Comparative Efficacy of Colonoscope Distal Attachment Devices in Increasing Rates of Adenoma Detection:
Antonio Facciorusso1, Valentina Del Prete1, Rosario Vincenzo Buccino1
1Gastroenterology Unit, Department of Medical Sciences, University of Foggia, Foggia, Italy.
Background & Aims:
Several add-on devices have been developed to increase rates of colon adenoma detection (ADR). We assessed their overall and comparative efficacy, and estimated absolute magnitude of benefit through a network meta-analysis.
Methods:
We searched the PubMed/Medline and Embase database through March 2017 and identified 25 randomized controlled trials (comprising 16,103 patients) that compared the efficacy of add-on devices (cap; Endocuff; Arc Medical Design Ltd, Leeds, UK, and Endorings; Us Endoscopy, Mentor, OH) with each other or with standard colonoscopy. The primary outcome was ADR; secondary outcomes included rate of polyp detection, and rate of and time to cecal intubation. We performed pairwise and network meta-analyses, and appraised quality of evidence using Grading of Recommendations Assessment, Development and Evaluation. We estimated the magnitude of increase in ADR by low-performing endoscopists (baseline ADR, 10%) and high-performing endoscopists (baseline ADR, 40%) with use of these devices.
Results:
Overall, distal attachment devices increased ADR compared with standard colonoscopy (relative risk [RR], 1.13; 95% CI, 1.03-1.23; low-quality evidence), with potential absolute increases in ADR to 11.3% for low-performing endoscopists and to 45.2% for high-performing endoscopists. In a comparative evaluation, we found low-quality evidence that Endocuff increases ADR compared with standard colonoscopy (RR, 1.21; 95% CI, 1.03-1.41), with anticipated increases in ADR to 12% for low-performing endoscopists and to 48% for high-performing endoscopists. We found very low quality evidence to support the use of Endorings (RR, 1.70; 95% CI, 0.86-3.36) or caps (RR, 1.07; 95% CI, 0.96-1.19) vs standard colonoscopy for increasing ADR. The benefit of one distal attachment device over another was uncertain due to very low quality evidence.
Conclusions:
Based on network meta-analysis, we anticipate only modest improvement in ADRs with use of distal attachment devices, especially in low-performing endoscopists.
More Related Videos
09:42Murine Endoscopy for In Vivo Multimodal Imaging of Carcinogenesis and Assessment of Intestinal Wound Healing and Inflammation
Published on: August 26, 2014
15:49Flexible Colonoscopy in Mice to Evaluate the Severity of Colitis and Colorectal Tumors Using a Validated Endoscopic Scoring System
Published on: October 16, 2013
Related Concept Videos
Endoscopic Procedures II: Colonoscopy
Endoscopic Procedures IV: Sigmoidoscopy and Laproscopy
Sigmoidoscopy
Sigmoidoscopy is a diagnostic procedure that uses a flexible sigmoidoscope equipped with a light source and camera to examine the rectum and sigmoid colon. The procedure involves inserting the tube through the anus...
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...