Improving PICC use and outcomes in hospitalised patients: an interrupted time series study using MAGIC criteria
Lakshmi Swaminathan1, Scott Flanders2, Mary Rogers2
1Internal Medicine, Beaumont Hospital Dearborn, Dearborn, Michigan, USA.
Background:
Although important in clinical care, reports of inappropriate peripherally inserted central catheter (PICC) use are growing.
Objective:
To test whether implementation of the Michigan Appropriateness Guide for Intravenous Catheters (MAGIC) can improve PICC use and patient outcomes.
Design:
Quasi-experimental, interrupted time series design at one study site with nine contemporaneous external controls.
Setting:
Ten hospitals participating in a state-wide quality collaborative from 1 August 2014 to 31 July 2016.
Patients:
963 hospitalised patients who received a PICC at the study site vs 6613 patients at nine control sites.
Intervention:
A multimodal intervention (tool, training, electronic changes, education) derived from MAGIC.
Measurements:
Appropriateness of PICC use and rates of PICC-associated complications. Segmented Poisson regression was used for analyses.
Results:
Absolute rates of inappropriate PICC use decreased substantially at the study site versus controls (91.3% to 65.3% (-26.0%) vs 72.2% to 69.6% (-2.6%); P<0.001). After adjusting for underlying trends and patient characteristics, however, a marginally significant 13.8% decrease in inappropriate PICC use occurred at the study site (incidence rate ratio 0.86 (95% CI 0.74 to 0.99; P=0.048)); no change was observed at control sites. While the incidence of all PICC complications decreased to a greater extent at the study site, the absolute difference between controls and intervention was small (33.9% to 26.7% (-7.2%) vs 22.4% to 20.8% (-1.6%); P=0.036).
Limitations:
Non-randomised design limits inference; the most effective component of the multimodal intervention is unknown; effects following implementation were modest.
Conclusions:
In a multihospital quality improvement project, implementation of MAGIC improved PICC appropriateness and reduced complications to a modest extent. Given the size and resources required for this study, future work should consider cost-to-benefit ratio of similar approaches.
Related Concept Videos
Endocarditis IV: Nursing Management
Methods of Documentation VI: Case Management Model
For example, a patient with a chronic...
Methods of Documentation III: PIE
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Acute Coronary Syndrome IV: Interprofessional Care
Nursing Clinical Information System
A Nursing Clinical Information System (NCIS) is a specialized type of healthcare information system tailored to meet the unique needs of nursing practice. It incorporates the principles of nursing informatics to streamline information management and improve the quality of care delivery.
Critical attributes of NCIS include: