Related Experiment Video
Updated: Feb 18, 2026

Application of Biochip Microfluidic Technology to Detect Serum Allergen-specific Immunoglobulin E sIgE
Published on: April 21, 2019
Comparison of allergen responses based on the TRUE Test and IQ Chamber system in Korean patients
Won Joo Kwon1, Joo Yeon Ko2, Young Suck Ro2
1Department of Dermatology, Hallym University Sacred Heart Hospital, Anyang, Korea.
Abstract:
A comparison between responses to allergens based on the TRUE Test®(TT) and IQ® Chamber (IQC) in Europeans has been previously reported, however, no such study has been performed in Asians. To compare allergen responses using the TT and IQC (using the Korean standard series) in order to gather more information regarding the positive response rates for each allergen and the clinical value of IQC. Suspected contact dermatitis patients were enrolled and tested with 18 allergens using the TT and IQC. The test was performed in 214 patients. Simultaneous positive results for both tests were recorded in 242 cases (positive concordance rate: 66.7%). IQC yielded more positive results. Allergens with a high positive concordance rate were nickel sulphate (82.1%), thimerosal (78.6%), and p-phenylenediamine (73.3%). IQC mostly showed similar or higher positive rates than TT, with high concordance. We recommend the IQC method as a screening test in patients with suspected contact dermatitis. To compensate for possible false positive results, careful history taking and a different patch test should be performed when appropriate.