Related Experiment Video
Updated: Aug 19, 2026

Expired CO2 Measurement in Intubated or Spontaneously Breathing Patients from the Emergency Department
Published on: January 29, 2011
The measurement of expiratory oxygen as disconnection alarm
R Knaack-Steinegger1, D A Thomson
1Department of Anesthesia, University of Basel/Kantonsspital, Switzerland.
Abstract:
The efficacy of an oxygen-monitoring alarm in the expiratory limb of an anesthetic circuit was evaluated as a method of detecting disconnections of the patient from the anesthetic machine. Oxygen concentrations were determined in the expiratory limb of a semiclosed anesthetic circuit with a ventilator and a 2-1 reservoir bag serving as a simple lung model. Adjustments of ventilation during the different measurements were a PEEP of 5 cmH2O, respiratory rates of 10/min and 5/min, and tidal volumes of 1,000 and 500 ml, respectively. The alarm time measured with a stopwatch was the time that elapsed between disconnection and the acoustical alarm. The circuit was always disconnected at the y-piece when the reservoir bag had been fully expanded after an inspiration. With various fresh flow rates and oxygen concentrations ranging from 33% to 52%, disconnection always was evident within 30 s. Measurement of the oxygen concentration with an alarm time of 30 s after disconnection may be an effective backing system for detecting a disconnection.
Related Concept Videos
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...