Tilt Testing with Combined Lower Body Negative Pressure: a "Gold Standard" for Measuring Orthostatic Tolerance
Published on: March 21, 2013
Normal Values of High-Resolution Manometry in Supine and Upright Positions in a Thai Population
Pitichote Hiranyatheb1,2, Suriya Chakkaphak3,4, Supphamat Chirnaksorn5,4
1Division of General Surgery, Department of Surgery, Faculty of Medicine, Ramathibodi Hospital, Mahidol University, 270 Rama VI Road, Ratchatewe, Bangkok, 10400, Thailand. pitichoteh@yahoo.com.
Background:
Although cut-off values used in high-resolution manometry (HRM) to diagnose esophageal motility disorders are based on representative samples of the US population and assume a supine position, differences in population and body positioning can reportedly affect results.
Aims:
To establish normal HRM values for Thai people in both supine and upright positions.
Methods:
Forty-one healthy subjects were recruited, each of whom underwent solid-state HRM with ten 5-mL swallows of water in both the supine and upright positions. Measuring parameters according to the Chicago classification criteria (CC v3.0) were included, for which the mean, median and 5th and 95th percentiles (PCTLs) were calculated.
Results:
The results corresponded with the CC v3.0 criteria, except for the mean, and 5th PCTL of the distal contractile integral (DCI), which were lower for this population. In the upright position, the mean and median values for DCI, intrabolus pressure and integrated relaxation pressure were significantly decreased, whereas the length of the transitional zone was significantly increased. The limitations of this study include: (1) the relatively low number of participants, (2) the limited recruitment of participants only at Ramathibodi Hospital and (3) the limited recruitment of only young and middle-aged participants.
Conclusions:
We established normal values for the HRM parameters in a representative sample of the Thai population. Our supine results still prove that the use of the CC v3.0 is preferable. HRM testing in patients measured in the upright position should be analyzed based on the normative values obtained from upright swallow studies.
Related Concept Videos
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Anatomical Positions
The body is upright, facing forward, and standing erect.
The feet are parallel and flat on the floor.
The arms are hanging by the...
Pre-Procedural Guidelines for Assessing Blood Pressure
Assessing Blood pressure in the Leg
Preparation:
Blood Pressure