Abstract:
We evaluated the safety and efficacy of high-dose topical and nebulized airway anesthesia in normal volunteers and in patients undergoing diagnostic fiberoptic bronchoscopy. Lidocaine solution (4 percent) was used for gargling, for spraying the palate and oropharynx with an atomizer, and for nebulization with an air-powered nebulizer (mean total dose, 1,682 mg) and 2 percent lidocaine (Xylocaine) jelly for anesthetizing nasal passages. In six normal subjects and in eight patients, lidocaine blood levels were measured at baseline, after gargling, after spraying, after nebulization, and then at 5, 10, 15, 30, and 60 min; 19 normal subjects and ten patients underwent the same anesthesia protocol but had no blood drawn. Fiberoptic bronchoscopy was performed in 21 normal volunteers and in 18 patients and cultures obtained using the protected specimen brush. Additional endobronchial lidocaine (mean 256 mg) was given to the 18 patients after collecting the microbiology specimens. Peak lidocaine blood levels remained below 6 micrograms/ml in all cases. Cough and discomfort during bronchoscopic examination was absent or minimal in 17 of 21 normal subjects (80 percent) and in 14 of 18 patients (77 percent) and was severe in only one instance (5 percent). There were no related complications. Using only topical and nebulized anesthesia is safe and effective for performing fiberoptic bronchoscopy, especially when bacterial cultures are to be obtained and endobronchial instillation of lidocaine must be avoided.
More Related Videos
Related Concept Videos
Inhalational Anesthetics: Overview
Endoscopic Studies I: Bronchoscopy and Thoracoscopy
Bronchoscopy
Description
Bronchoscopy is a procedure that involves direct visualization of the larynx, trachea, and bronchi for diagnostic and therapeutic purposes. A flexible fiber optic or rigid bronchoscope is used to carry out the procedure. The fiber-optic bronchoscope is more frequently used due to...
Endoscopic Studies II: Thoracocentesis
Description
Excess pleural fluid or air may accumulate in some respiratory disorders in the thoracic cavity. To treat pleural effusion, a physician conducts thoracentesis by carefully piercing the chest wall and entering...
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...