Adaptive integrated parallel reception, excitation, and shimming (iPRES-A) with microelectromechanical systems
Dean Darnell1,2, Yixin Ma1,2, Hongyuan Wang1,3
1Brain Imaging and Analysis Center, Duke University, Durham, North Carolina, USA.
Purpose:
Integrated parallel reception, excitation, and shimming coil arrays with N shim loops per radio-frequency (RF) coil element (iPRES(N)) allow an RF current and N direct currents (DC) to flow in each coil element, enabling simultaneous reception/excitation and shimming of highly localized B0 inhomogeneities. The purpose of this work was to reduce the cost and complexity of this design by reducing the number of DC power supplies required by a factor N, while maintaining a high RF and shimming performance.
Methods:
In the proposed design, termed adaptive iPRES(N) (iPRES(N)-A), each coil element only requires one DC power supply, but uses microelectromechanical systems switches to adaptively distribute the DC current into the appropriate shim loops to generate the desired magnetic field for B0 shimming. Proof-of-concept phantom experiments with an iPRES(2)-A coil and simulations in the human abdomen with an 8-channel iPRES(4)-A body coil array were performed to demonstrate the advantages of this innovative design.
Results:
The iPRES(2)-A coil showed no loss in signal-to-noise ratio and provided a much more effective correction of highly localized B0 inhomogeneities and geometric distortions than an equivalent iPRES(1) coil (88.2% vs. 32.2% lower B0 root-mean-square error). The iPRES(4)-A coil array showed a comparable shimming performance as that of an equivalent iPRES(4) coil array (52.6% vs. 54.2% lower B0 root-mean-square error), while only requiring 8 instead of 32 power supplies.
Conclusion:
The iPRES(N)-A design retains the ability of the iPRES(N) design to shim highly localized B0 inhomogeneities, while drastically reducing its cost and complexity. Magn Reson Med 80:371-379, 2018. © 2017 International Society for Magnetic Resonance in Medicine.
More Related Videos
06:51Microparticle Manipulation by Standing Surface Acoustic Waves with Dual-frequency Excitations
Published on: August 21, 2018
09:01Gain-compensation Methodology for a Sinusoidal Scan of a Galvanometer Mirror in Proportional-Integral-Differential Control Using Pre-emphasis Techniques
Published on: April 4, 2017
Related Concept Videos
Electro-mechanical Systems
A key component of the DC motor is the armature, a rotating circuit positioned within a magnetic field. As an electric current passes through the...
Design Example
Design Example: Capacitance Multiplier Circuit
The circuit illustrated in Figure 1 below incorporates two op-amps, with the first operating as a voltage follower and the second acting as an inverting amplifier.