On the use of bolus for pacemaker dose measurement and reduction in radiation therapy
Huagang Yan1,2, Fanqing Guo1, Dengsong Zhu3
1Department of Therapeutic Radiology, Yale University School of Medicine, Yale-New Haven Hospital, New Haven, CT, USA.
Abstract:
Special attention is required in planning and administering radiation therapy to patients with cardiac implantable electronic devices (CIEDs), such as pacemaker and defibrillator. The range of dose to CIEDs that can induce malfunction is large among CIEDs. Clinically significant defects have been reported at dose as low as 0.15 Gy. Therefore, accurate estimation of dose to CIED and dose reduction are both important even if the dose is expected to be less than the often-used 2-Gy limit. We investigated the use of bolus in in vivo dosimetry for CIEDs. Solid water phantom measurements of out-of-field dose for a 6-MV beam were performed using parallel plate chamber with and without 1- to 2-cm bolus covering the chamber. In vivo dosimetry at skin surface above the CIED was performed with and without bolus covering the CIED for three patients with the CIED <5 cm from the field edge. Chamber measured dose at depth ~0.5-1.5 cm below the skin surface, where the CIED is normally located, was reduced by ~7-48% with bolus. The dose reduction became smaller at deeper depths and with smaller field size. In vivo dosimetry at skin surface also indicated ~20%-60% lower dose when using bolus for the three patients. The dose measured with bolus more accurately reflects the dose to CIED and is less affected by contaminant electrons and linac head scatter. In general, the treatment planning system (TPS) calculation underestimated the dose to CIED, but it predicts the CIED dose more accurately when bolus is used. We recommend the use of 1- to 2-cm bolus to cover the CIED during in vivo CIED dose measurements for more accurate CIED dose estimation. If the CIED is placed <2 cm in depth and its dose is mainly from anterior beams, we recommend using the bolus during the entire course of radiation delivery to reduce the dose to CIED.
More Related Videos
11:38Voluntary Breath-hold Technique for Reducing Heart Dose in Left Breast Radiotherapy
Published on: July 3, 2014
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
Related Concept Videos
Dose Size and Dosing Frequency: Determination Methods
One-Compartment Open Model for IV Bolus Administration: General Considerations
The drug's presence in the body is defined by an equation representing the difference between the rates of drug entry and exit. Key parameters—elimination rate constant,...
One-Compartment Open Model for IV Bolus Administration: Estimation of Clearance
In the one-compartment open model for intravenous (IV) bolus administration, clearance is estimated by dividing the elimination rate by the plasma drug concentration. This equation leverages the elimination rate constant and the apparent...
IV Infusion to Oral Dosing: Conversion Methods
Two-Compartment Open Model: IV Bolus Administration
The disparity between drug input and the sum of drug transfer rates between...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...