Objectives:
To determine if home blood pressure measurement (HBPM) provides comparable results to clinic blood pressure (BP) measurement.
Study Design:
A prospective, single-centre study of 37 pregnant and early post-partum women with a hypertensive pregnancy or at high-risk of developing a hypertensive pregnancy were asked to perform HBPM for a minimum period of one week. This was subsequently compared to clinic BP measurement both before and after the period of home measurement.
Main Outcome Measures:
The accuracy of HBPM compared to clinic measurement, and the acceptability by patients for HBPM.
Results:
The HBPM was comparable to clinic measurements [for the systolic blood pressure (SBP), the mean home reading was 123.4mmHg (122.0-124.9mmHg) versus 123.9mmHg (121.3-126.5mmHg) for the clinic reading (p=0.69); for the diastolic blood pressure (DBP) the mean home reading was 81.6mmHg (80.4-82.8mmHg) versus 84.4mmHg (82.6-86.2mmHg) for the clinic (p<0.01)]. There were no reported issues associated with the use of HBPM, but it did lead to 5 women contacting health care professionals for management of their BP between clinic visits.
Conclusions:
HBPM provides comparable results to the clinic BP measurement. It is also an acceptable technique for pregnant and early post-partum women. However, it should be used as an adjunct to clinic measurement, and cannot at this present stage replace clinic visits or clinic BP measurement.
Related Concept Videos
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Pre-Procedural Guidelines for Assessing Blood Pressure
Assessment of blood pressure in brachial artery(two-step method)
Measurement of Blood Pressure
Hypertension III: Clinical Manifestations and Diagnostic Studies
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...