Related Experiment Video
Updated: Feb 18, 2026

Robotic Myotomy and Partial Fundoplication for Achalasia
Published on: August 11, 2023
Improved Assessment of Bolus Clearance in Patients With Achalasia Using High-Resolution Impedance Manometry
Dustin A Carlson1, Claire A Beveridge1, Zhiyue Lin1
1Division of Gastroenterology and Hepatology, Department of Medicine, Feinberg School of Medicine, Northwestern University, Chicago, Illinois.
Background & Aims:
Esophageal retention is typically evaluated by timed-barium esophagram in patients treated for achalasia. Esophageal bolus clearance can also be evaluated using high-resolution impedance manometry. We evaluated the associations of conventional and novel high-resolution impedance manometry metrics, esophagram, and patient-reported outcomes (PROs) in achalasia.
Methods:
We performed a prospective study of 70 patients with achalasia (age, 20-81 y; 30 women) treated by pneumatic dilation or myotomy who underwent follow-up evaluations from April 2013 through December 2015 (median, 12 mo after treatment; range, 3-183 mo). Patients were assessed using timed-barium esophagrams, high-resolution impedance manometry, and PROs, determined from Eckardt scores (the primary outcome) and the brief esophageal dysphagia questionnaire. Barium column height was measured from esophagrams taken 5 minutes after ingestion of barium (200 mL). Impedance-manometry was analyzed for bolus transit (dichotomized) and with a customized MATLAB program (The MathWorks, Inc, Natick, MA) to calculate the esophageal impedance integral (EII) ratio.
Results:
Optimal cut points to identify a good PRO (defined as Eckardt score of ≤3) were esophagram barium column height of 3 cm (identified patients with a good PRO with 63% sensitivity and 75% specificity) and an EII ratio of 0.41 (identified patients with a good PRO with 83% sensitivity and 75% specificity). Complete bolus transit identified patients with a good PRO with 28% sensitivity and 75% specificity. Of the 25 patients who met these cut points for both esophagram barium column height and EII ratio, 23 (92%) had a good PRO. Of the 17 patients who met neither cut point, 14 (82%) had a poor PRO (Eckardt score above 3).
Conclusions:
In a prospective study of 70 patients with achalasia, we found EII ratio identified patients with good PROs with higher levels of sensitivity (same specificity) than timed-barium esophagram or impedance-manometry bolus transit assessments. The EII ratio should be added to achalasia outcome evaluations that involve high-resolution impedance manometry as an independent measure and to complement timed-barium esophagram.
Related Concept Videos
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Upper GI Series: Barium Swallow
Purpose and Procedure
Patients undergoing this procedure ingest a liquid containing barium sulfate with a chalky...
One-Compartment Open Model for IV Bolus Administration: Estimation of Clearance
In the one-compartment open model for intravenous (IV) bolus administration, clearance is estimated by dividing the elimination rate by the plasma drug concentration. This equation leverages the elimination rate constant and the apparent...
Gastric Emptying
Gastric Motility
Peristaltic Waves and Chyme Formation
Upon food entry, the stomach initiates...

