Related Experiment Video
Updated: Feb 18, 2026

Analysis of Volatile and Oxidation Sensitive Compounds Using a Cold Inlet System and Electron Impact Mass Spectrometry
Published on: September 5, 2014
Carbon Fiber Ionization Mass Spectrometry for the Analysis of Analytes in Vapor, Liquid, and Solid Phases
Min-Li Wu1, Te-Yu Chen1, Yen-Chun Chen1
1Department of Applied Chemistry, National Chiao Tung University , Hsinchu 300, Taiwan.
Abstract:
Various ionization methods in mass spectrometry (MS) are available for the analysis of analytes with different properties. Nonetheless, the use of a single ionization method to analyze mixtures containing analytes with different polarities and volatilities in different phases at atmospheric pressure remains a challenge. Exploring an ionization method that can ionize small organics and large biomolecules with different properties for MS analysis is advantageous. Carbon fiber ionization mass spectrometry (CFI-MS), which uses a carbon fiber bundle as the ion source, is useful for the analysis of small organics with low polarities. Voltage needs to be applied on the carbon fiber bundle to initiate corona discharge for ionization of analytes. In this study, we explore the suitability of using CFI-MS in the analysis of analytes in vapor, liquid, and solid phases using a single carbon fiber (length : ∼1 cm; diameter: ∼10 μm) as the ion source. Furthermore direct electric contact on the carbon fiber is not required. We demonstrate that CFI-MS is useful for analyzing not only small and low-polarity organics but also polar biomolecules, such as peptides and proteins. The limits of detection for analytes with high polarities such as dodecyl trimethylammonium bromide and bradykinin are estimated to be ∼16 and ∼53 pM, respectively. Ionization mechanisms, including corona discharge and electrospray, are involved in the ionization of analytes with the polarity from low to high. Furthermore, sesame oil containing aromatic volatiles and compounds with different polarities is used as a model sample to demonstrate the capability of the developed ionization method to provide comprehensive chemical information from a complex sample. In addition, the feasibility of using the developed method for quantitative analysis of nonpolar as well as medium and high polarity analytes is also demonstrated. The sensitivity of the developed method toward analytes with high polarity is higher than those with low polarity. The method precision was estimated to be ∼7.8%.
More Related Videos
08:10Fizzy Extraction of Volatile Organic Compounds Combined with Atmospheric Pressure Chemical Ionization Quadrupole Mass Spectrometry
Published on: July 14, 2017
07:24Combustion Chemistry of Fuels: Quantitative Speciation Data Obtained from an Atmospheric High-temperature Flow Reactor with Coupled Molecular-beam Mass Spectrometer
Published on: February 19, 2018
Related Concept Videos
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Chemical Ionization (CI) Mass Spectrometry
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Mass Spectrometers
Mass Spectrometry: Overview
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...