Maisha M Khan1,2, Nathan Herrmann1,3, Damien Gallagher3
1Neuropsychopharmacology Research Group, Hurvitz Brain Sciences Program, Sunnybrook Research Institute, Toronto, Ontario, Canada.
Objectives:
To quantitatively summarize changes in cognitive performance in individuals with severe aortic stenosis undergoing transcatheter aortic valve implantation (TAVI).
Design:
Metaanalysis.
Participants:
Individuals undergoing TAVI (N = 1,065 (48.5% male) from 18 studies, average age ≥80).
Measurements:
The MEDLINE, EMBASE, and Cochrane Central databases were searched for original peer-reviewed reports assessing cognitive performance using standardized cognitive tests before and after TAVI. Data were extracted for cognitive scores before TAVI; perioperatively (within 7 days after TAVI); 1, 3, and 6 months after TAVI, and 12 to 34 months after TAVI (over the long term). Standardized mean differences (SMDs) were generated using random-effects models for changes in cognition at each time point. Metaregression analyses were conducted to assess the association between population and procedural characteristics and cognitive outcomes. Risk of bias was assessed.
Results:
There were no significant changes from baseline in perioperative cognitive performance (SMD = 0.05, 95% confidence interval (CI) = -0.08-0.18; z = 0.75, P = .46), although overall cognitive performance had improved significantly 1 month after TAVI (SMD = -0.33, 95% CI = -0.50 to -0.16; z = 3.83, P < .001). There were no differences in cognitive performance 3 and 6 months after TAVI or over the long term. Cognitive outcomes were not associated with any covariates in regression analyses.
Conclusion:
Cognitive performance is preserved after TAVI, suggesting TAVI is not detrimental to cognition.
More Related Videos
06:59Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation
Published on: June 3, 2018
09:57Four-Dimensional Computed Tomography-Guided Valve Sizing for Transcatheter Pulmonary Valve Replacement
Published on: January 20, 2022
Related Concept Videos
Aortic Regurgitation III: Medical Management
Mitral Valve Prolapse II: Assessment and Management
Mitral Stenosis III: Medical Management
Acute Coronary Syndrome III: Diagnostic Studies
Mitral Regurgitation III: Medical Management
Aortic Regurgitation II: Clinical Features and Diagnostic Tests