Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Talin1 Adhesion Morphology and Colocalization With Tensin3 Are Largely Unaffected by Polyacrylamide Substrate Stiffness.

Cytoskeleton (Hoboken, N.J.)·2026
Same author

Methodological study of fibroblasts MEF 3T3 heterogeneity cultured on hydrogel substrates with different surface functionalization.

bioRxiv : the preprint server for biology·2025
Same author

A Review of Talin- and Integrin-Dependent Molecular Mechanisms in Cancer Invasion and Metastasis.

International journal of molecular sciences·2025
Same author

From fixed-dried to wet-fixed to live - comparative super-resolution microscopy of liver sinusoidal endothelial cell fenestrations.

Nanophotonics (Berlin, Germany)·2024
Same author

Multimodal analysis of traction forces and the temperature dynamics of living cells with a diamond-embedded substrate.

Biomedical optics express·2024
Same author

Cell-particles interaction - selective uptake and transport of microdiamonds.

Communications biology·2024

Related Experiment Video

Updated: Feb 18, 2026

Integrated Cell Manipulation Platform Coupled with the Single-probe for Mass Spectrometry Analysis of Drugs and Metabolites in Single Suspension Cells
07:55

Integrated Cell Manipulation Platform Coupled with the Single-probe for Mass Spectrometry Analysis of Drugs and Metabolites in Single Suspension Cells

Published on: June 21, 2019

6.2K

Precise mass determination of single cell with cantilever-based microbiosensor system.

Bogdan Łabędź1, Aleksandra Wańczyk1, Zenon Rajfur1

  • 1Institute of Physics; Faculty of Physics, Astronomy and Applied Computer Science, Jagiellonian University, Krakow, Poland.

Plos One
|November 22, 2017
PubMed
Summary

This study used a biosensor to measure the mass of a single yeast cell with high precision. The researchers found that the cell's position on the sensor significantly affects the measurement accuracy. By accounting for this position, they achieved threefold better accuracy than previous methods. They also observed that storing cells for six months increased their mass, indicating that environmental factors influence cell integrity. These findings suggest that biosensors can be more reliable when precise positioning and storage conditions are used.

Keywords:
single-cell massbiosensor technologyyeast cell measurementmicrocantilever system

Frequently Asked Questions

More Related Videos

Nanomechanics of Drug-target Interactions and Antibacterial Resistance Detection
11:56

Nanomechanics of Drug-target Interactions and Antibacterial Resistance Detection

Published on: October 25, 2013

14.7K
Applications of the Single-probe: Mass Spectrometry Imaging and Single Cell Analysis under Ambient Conditions
15:00

Applications of the Single-probe: Mass Spectrometry Imaging and Single Cell Analysis under Ambient Conditions

Published on: June 14, 2016

11.3K

Related Experiment Videos

Last Updated: Feb 18, 2026

Integrated Cell Manipulation Platform Coupled with the Single-probe for Mass Spectrometry Analysis of Drugs and Metabolites in Single Suspension Cells
07:55

Integrated Cell Manipulation Platform Coupled with the Single-probe for Mass Spectrometry Analysis of Drugs and Metabolites in Single Suspension Cells

Published on: June 21, 2019

6.2K
Nanomechanics of Drug-target Interactions and Antibacterial Resistance Detection
11:56

Nanomechanics of Drug-target Interactions and Antibacterial Resistance Detection

Published on: October 25, 2013

14.7K
Applications of the Single-probe: Mass Spectrometry Imaging and Single Cell Analysis under Ambient Conditions
15:00

Applications of the Single-probe: Mass Spectrometry Imaging and Single Cell Analysis under Ambient Conditions

Published on: June 14, 2016

11.3K

Area of Science:

  • Cell biology and biophysics
  • Microsensor technology
  • Analytical biochemistry

Background:

Prior research has shown that measuring cell mass is a complex task, especially when dealing with single cells. It was already known that traditional methods often lack the precision needed for such small-scale measurements. This gap motivated the development of more sensitive tools like microcantilever-based biosensors. No prior work had resolved the issue of how cell positioning affects mass readings. Established knowledge includes the use of biosensors for detecting biological interactions, but their application to single-cell mass determination remains limited. That uncertainty drove the need for a more accurate and reliable system. The challenge lies in achieving consistent measurements while accounting for variables like cell placement and environmental factors. This study builds on prior methods but introduces a novel approach to enhance precision.

Purpose Of The Study:

The aim of this study was to determine the dry mass of a single yeast cell with high accuracy using a microcantilever biosensor. The specific problem addressed is the variability in mass readings caused by cell positioning on the sensor. The motivation stems from the need for reliable single-cell measurements in biological and medical research. The study also sought to examine how storage duration affects cell mass. This work is part of a broader effort to refine biosensing technologies for cell analysis. The researchers propose that precise positioning can significantly improve measurement accuracy. By comparing different positioning scenarios, the study aims to establish a more robust method for mass determination. The findings could help standardize biosensor use in cell biology.

Main Methods:

The study used a microcantilever biosensor called Cantisens CSR-801 to measure the dry mass of individual yeast cells. The device was calibrated to detect minute changes in mass based on cantilever deflection. Researchers placed cells at various positions along the cantilever's length to assess positioning effects. Calculations were performed to compare mass readings with and without accounting for cell placement. The system was tested under controlled conditions to minimize external variables. Storage time was also factored in by measuring cells after six months. The approach combined experimental measurements with mathematical modeling to improve accuracy. The results were validated by comparing them to prior estimates in the literature.

Main Results:

The dry mass of a single yeast cell was measured as 47.65 ± 1.05 pg using the biosensor. The study found that cell position on the cantilever significantly affects mass readings. Calculations that account for cell position improved accuracy by a factor of three. This improvement highlights the importance of precise cell placement in biosensing applications. Storage time was found to influence cell mass, with an increase observed after six months. The variation in mass suggests that environmental factors affect cell integrity over time. The results provide a more reliable method for measuring single-cell mass than previous approaches. These findings support the use of microcantilever systems for high-precision biological measurements.

Conclusions:

The authors state that cell positioning is a critical factor in achieving accurate mass measurements with biosensors. They propose that accounting for cell placement improves measurement precision by threefold. The study also suggests that storage duration affects cell mass, indicating a need for controlled storage conditions. These findings support the use of microcantilever systems for single-cell analysis. The researchers emphasize the importance of precise calibration and positioning protocols. The results do not suggest that this method is essential for all cell types but may be applicable to similar systems. The study does not propose new drug targets or future research directions beyond refining biosensor use. The conclusions are limited to the specific system and conditions tested in the experiment.

The dry mass of a single yeast cell was found to be 47.65 ± 1.05 pg using the Cantisens CSR-801 biosensor.

The study found that cell position along the cantilever's length significantly affects mass readings, with precise placement improving accuracy by threefold.

The researchers propose that accounting for cell position improves measurement accuracy by threefold, as opposed to assuming uniform mass distribution.

The biosensor was used to measure the dry mass of individual yeast cells by detecting cantilever deflection caused by cell mass.

The study found that after six months of storage, the average mass of a single yeast cell increased, suggesting environmental effects.

The authors suggest that precise cell positioning and controlled storage conditions are important for accurate biosensor measurements.