X-ray Dose Reduction through Adaptive Exposure in Fluoroscopic Imaging
Published on: September 11, 2011
Modern Fixed Imaging Systems Reduce Radiation Exposure to Patients and Providers
Lars Stangenberg1,2, Fahad Shuja1,3, I Martijn J van der Bom4
11 Division of Vascular and Endovascular Surgery, Department of Surgery, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA, USA.
Abstract:
High-definition fluoroscopic imaging is required to perform endovascular procedures safely and precisely, especially in complex cases, resulting in longer procedures and increased radiation exposure. This is of importance for training institutions as trainees, even with sound instruction in as low as reasonably achievable (ALARA) principles, tend to have high radiation exposures. Recently, there was an upgrade in the imaging system allowing for comparison of radiation exposure to patients and providers. We performed an analysis of consecutive endovascular aneurysm repair (EVAR) and superficial femoral artery (SFA) interventions in the years 2013 to 2014. We recorded body mass index (BMI) and fluoroscopy time (FT) and subsequently matched 1:1 based on BMI, FT, or both. We determined radiation dose using air kerma (AK) and also recorded individual surgeons' badge readings. Allura Xper FD20 was upgraded to AlluraClarity with ClarityIQ. We identified a total of 77 EVARs (52 pre and 25 post) and 134 SFA interventions (99 pre and 35 post). Unmatched results for EVAR were BMI pre 26.2 versus post 25.8 (kg/m2, P = .325), FT 28.1 versus 21.2 (minutes, P = .051), and AK 1178.5 versus 581 (mGy, P < .001), respectively. After matching, there was a 53.2% reduction in AK (846.1 vs 395.9 mGy; P = .004) for EVAR. Unmatched results for SFA interventions were BMI pre 28.1 versus post 26.6 ( P = .327), FT 18.7 versus 16.2 ( P = .282), and AK 285.6 versus 106.0 ( P < .001), respectively. After matching, there was a 57.0% reduction in AK (305.0 vs 131.3, P < .001). The total deep dose equivalent from surgeons' badge readings decreased from 39.5 to 17 mrem ( P = .029). Aortic and peripheral endovascular interventions can be performed with reduced radiation exposure to patients and providers, employing modern fixed imaging systems with advanced dose reduction technology. This is of particular importance in the light of the increasing volume and complexity of endovascular and hybrid procedures as well as the prospect of decades of radiation exposure during training and practice.
More Related Videos
Related Concept Videos
X-ray Imaging
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Radiological Investigation I: X-ray and CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Magnetic Resonance Imaging