Related Experiment Video
Updated: Feb 18, 2026

Laser-heating and Radiance Spectrometry for the Study of Nuclear Materials in Conditions Simulating a Nuclear Power Plant Accident
Published on: December 14, 2017
System Validation Experiments for Obtaining Tracer Laser-Induced Fluorescence Data at Elevated Pressure and
Jason Hartwig1, Gaurav Mittal2, Kamal Kumar3
11 Department of Mechanical and Aerospace Engineering, Case Western Reserve University, Cleveland, OH, USA.
Abstract:
This paper presents a set of system validation experiments that can be used to qualify either static or flow experimental systems for gathering tracer photophysical data or conducting laser diagnostics at high pressure and temperature in order to establish design and operation limits and reduce uncertainty in data interpretation. Tests demonstrated here quantify the effect of tracer absorption at the test cell walls, stratification, photolysis, pyrolysis, adequacy of mixing and seeding, and reabsorption of laser light using acetone as the tracer and 282 nm excitation. Results show that acetone exhibits a 10% decrease in fluorescence signal over 36 000 shots at 127.4 mJ/cm2, and photolysis is negligible below 1000 shots collected. Meanwhile, appropriately chosen gas residence times can mitigate risks due to pyrolysis and inadequate mixing and seeding; for the current work 100 ms residence time ensured <0.5% alteration of tracer number density due to thermal destruction. Experimental results here are compared to theoretical values from the literature.