Investigation into Deep Breathing through Measurement of Ventilatory Parameters and Observation of Breathing Patterns
Published on: September 16, 2019
Analysis of breathing via optoelectronic systems: comparison of four methods for computing breathing volumes and
Carlo Massaroni1, Guglielmo Senesi1, Emiliano Schena1
1a Unit of Measurements and Biomedical Instrumentation, Departmental Faculty of Engineering , Università Campus Bio-Medico di Roma , Rome , Italy.
Abstract:
Breathing parameters can be measured by motion capture systems by placing photo-reflective markers on the chest wall. A computational model is mandatory to compute the breathing volume and to calculate temporal and kinematical features by the gathered markers trajectories. Despite different methods based on different geometrical approaches can be adopted to compute volumes, no information about their differences in the respiratory evaluation are available. This study investigated the performances of four methods (conventional, prism-based, convex hull with boundary condition, based on Delaunay triangulation) using an optoelectronic motion capture system, on twelve healthy participants during 30 s of breathing. Temporal trends of volume traces, tidal volume values, and breathing durations were compared between methods and spirometry (used as reference instrument). Additionally, thoraco-abdominal motion patterns were compared between methods by analysing the compartmental contributions and their variability. Results shows comparable similarities between the volume traces obtained using spirometry, prism-based and conventional methods. Prism-based and convex hull with boundary condition methods show lower bias in tidal volumes estimation up to 0.06 L, compared to the conventional and Delaunay triangulation methods. Prism-based method shows maximum differences of 30 mL in the comparison of compartmental contributions to the total volume, by resulting in a maximum deviation of 1.6% in the percentage contribution analysis. In conclusion, our finding demonstrated the accuracy of the non-invasive MoCap-based breathing analysis with the prism-based method tested. Data provided in this study will lead researchers and clinicians in the computational method choice for temporal and volumetric breathing analysis.
Related Concept Videos
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Respiratory Volumes
Tidal Volume (TV) Tidal volume (TV) is the air inhaled or exhaled in a...
Application of Integration: Problem Solving
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Physical Assessment of the Respiratory Tract II: Inspection
Chest Configuration
The chest configuration...
Mechanism of Breathing II: Expiration
Expiration, or exhaling, is a complex physiological process that begins as the inspiratory muscles begin to relax. This relaxation triggers a series of events that epitomize the efficiency of the respiratory system.
Mechanism of Expiration: