Related Experiment Video
Updated: Feb 18, 2026

Experimental Protocol to Investigate Particle Aerosolization of a Product Under Abrasion and Under Environmental Weathering
Published on: September 16, 2016
Using a Particle Counter to Inform the Creation of Similar Exposure Groups and Sampling Protocols in a Structural
James Mino1, Bernadette Quémerais2
1Division of Preventive Medicine, University of Alberta, Edmonton, AB T6G 2S2, Canada. jmino@ualberta.ca.
Abstract:
The objective of this project was to create similar exposure groups (SEGs) for occupational monitoring in a structural steel fabrication facility. Qualitative SEG formation involved worksite observation, interviews, and audits of materials and procedures. These were supplemented with preliminary task-based shop survey data collected using a condensation particle counter. A total of six SEGs were formed, with recommendations for occupational exposure sampling for five groups, as well as ambient sampling recommendations to address areas on the operational floor found to have higher particle concentrations. The combination of direct reading device data and qualitative SEG formation techniques is a valuable approach, as it contains both the monetary and temporal costs of worksite exposure monitoring. This approach also provides an empowering in-house analysis of potentially problematic areas, and results in the streamlining of occupational exposure assessment.