Related Experiment Video
Updated: Feb 18, 2026

Manufacturing Abdominal Aorta Hydrogel Tissue-Mimicking Phantoms for Ultrasound Elastography Validation
Published on: September 19, 2018
Applicability of simplified computational models in prediction of peak wall stress in abdominal aortic aneurysms
Abstract:
In the paper impact of different material models on the calculated peak wall stress (PWS) and peak wall rupture risk (PWRR) in abdominal aortic aneurysms (AAAs) is assessed. Computational finite element models of 70 patient-specific AAAs were created using two different material models - a realistic one based on mean population results of uniaxial tests of AAA wall considered as reference, and a 100 times stiffer artificial model. The calculated results of PWS and PWRR were tested to evaluate statistical significance of differences caused by the non-realistic material model. It was shown that for majority of AAAs the differences are insignificant but for some 10% of them their relative differences exceed 20% which may lead to incorrect decisions on their surgical treatment. This percentage of failures favours application of realistic material models in clinical practise although they are much more time-consuming.
More Related Videos
09:32Measurement of Pulse Propagation Velocity, Distensibility and Strain in an Abdominal Aortic Aneurysm Mouse Model
Published on: February 23, 2020
06:18Intravascular Ultrasound Image-Based Finite Element Modeling Approach for Quantifying In Vivo Mechanical Properties of Human Coronary Artery
Published on: December 6, 2024