Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen01:16

Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen

2.6K
Oxygen therapy is a pivotal aspect of medical care, particularly for patients with respiratory ailments. Two prominent oxygen-delivering systems include the Venturi mask and the transtracheal oxygen catheter.
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
2.6K
Oxygen Delivering System I: Nasal Cannula and Face Mask01:26

Oxygen Delivering System I: Nasal Cannula and Face Mask

1.8K
The human body requires oxygen to function, and when the natural process of respiration is hindered, external devices, including the following, are needed to help deliver this vital gas.
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
1.8K
Pulse Oximetry01:24

Pulse Oximetry

1.4K
Pulse oximetry, or SpO2, is a non-invasive method for continuously monitoring arterial oxygen saturation (SaO2). This procedure involves attaching a probe or sensor to the patient's fingertip, forehead, earlobe, or nose bridge. The sensor works by detecting changes in oxygen saturation levels through light signals generated by the oximeter and reflected by the pulsing blood under the probe.
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
1.4K
Mechanical Ventilation III: Noninvasive Ventilation01:23

Mechanical Ventilation III: Noninvasive Ventilation

628
Noninvasive positive-pressure ventilation (NIPPV), continuous positive airway pressure (CPAP), and bilevel positive airway pressure (BiPAP) are essential methods in respiratory care. These ventilation techniques offer unique benefits for patients with various respiratory conditions, providing adequate support without requiring intubation. Let's explore how each method is crucial in improving patient outcomes and enhancing respiratory therapy.
Noninvasive Positive-Pressure Ventilation...
628

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Evaluation of Drug Stability Under Real-World Environmental Stress in Emergency Medical Service Setting in Qatar: A 1-Year Study.

The Journal of emergency medicine·2026
Same author

Knowledge, attitudes, and practices of pre-hospital emergency medical care practitioners regarding sepsis recognition: a cross-sectional study in Qatar.

BMC emergency medicine·2026
Same author

ELSO 2025 Narrative Guideline on ECMO Training and Continuing Education.

ASAIO journal (American Society for Artificial Internal Organs : 1992)·2026
Same author

Closing the loop: A systematic review of artificial intelligence in circular e-waste management.

Waste management (New York, N.Y.)·2026
Same author

Interfacility Transport of Emergency Patients by Helicopter Emergency Medical Services Versus Ground Emergency Medical Services.

Prehospital emergency care·2026
Same author

Stress and PTSD levels among Hamad Medical Corporation Paramedics before and during the COVID-19 pandemic.

Qatar medical journal·2026

Related Experiment Video

Updated: Feb 18, 2026

A Model to Simulate Clinically Relevant Hypoxia in Humans
09:54

A Model to Simulate Clinically Relevant Hypoxia in Humans

Published on: December 22, 2016

9.4K

Revolutionizing ECMO simulation with affordable yet high-Fidelity technology

Mohammed Al Disi1, Abdullah Alsalemi1, Yahya Alhomsi1

  • 1Department of Electrical Engineering, Qatar University, P.O. Box 2713, Doha, Qatar(1).

The American Journal of Emergency Medicine
|November 28, 2017
PubMed
Summary

No abstract available in PubMed .

Keywords:
And modularityECMO simulationExtracorporeal membrane oxygenation (ECMO)Physical FidelitySimulation-based training (SBT)Thermochromic ink

More Related Videos

Veno-Venous Extracorporeal Membrane Oxygenation in a Mouse
06:41

Veno-Venous Extracorporeal Membrane Oxygenation in a Mouse

Published on: October 24, 2018

13.1K
Evaluation of Right Ventricular Function in Experimental Models of Pulmonary Arterial Hypertension
10:03

Evaluation of Right Ventricular Function in Experimental Models of Pulmonary Arterial Hypertension

Published on: June 27, 2025

823

Related Experiment Videos

Last Updated: Feb 18, 2026

A Model to Simulate Clinically Relevant Hypoxia in Humans
09:54

A Model to Simulate Clinically Relevant Hypoxia in Humans

Published on: December 22, 2016

9.4K
Veno-Venous Extracorporeal Membrane Oxygenation in a Mouse
06:41

Veno-Venous Extracorporeal Membrane Oxygenation in a Mouse

Published on: October 24, 2018

13.1K
Evaluation of Right Ventricular Function in Experimental Models of Pulmonary Arterial Hypertension
10:03

Evaluation of Right Ventricular Function in Experimental Models of Pulmonary Arterial Hypertension

Published on: June 27, 2025

823