Related Experiment Video
Updated: Feb 18, 2026

Blood Flow Imaging with Ultrafast Doppler
Published on: October 14, 2020
3D ultrasound imaging in frequency domain based on concepts of array beam and synthetic aperture
Zhihui Han1, Hu Peng1, Xiaoyan Zhao1
1Department of Biomedical Engineering, Hefei University of Technology, Hefei 230009, China.
Abstract:
The high frame rate (HFR) imaging method has the ability to achieve a high frame rate. In this method, only one transmission is required to construct a frame of image. In our previous work, using a moved one-dimensional (1D) array transducer, a three-dimensional (3D) ultrasound imaging method in frequency domain was developed. This imaging method was designed based on the concepts of array beam and synthetic aperture, which can simplify the two-dimensional (2D) array transducer. In this paper, based on array beam and synthetic aperture, the HFR imaging method is demonstrated from a novel view. From this view, the relationship between the HFR imaging method and synthetic aperture is established with the weighting function of array beam. Besides, the HFR imaging method, the imaging method with a moved 1D array transducer, and the synthetic aperture imaging method with a moved single element transducer are unified in the same analytical method with different weighting functions. The same frequency domain signal processing flow can be applied to these imaging methods. Comparisons to these imaging methods are implemented with simulations. Simulation results show that, in the imaging depth of 45 mm, the resolutions calculated as the total width of the -6 dB main lobe in x-direction are 1.099 mm, 1.056 mm and 0.596 mm for the methods with 1D transducer, 2D transducer and the single element transducer, respectively. The resolution in y-direction is 1.054 mm for the methods with 2D transducer, and 0.565 mm, 0.593 mm for the 1D and single element transducers, respectively. The resolutions in z-direction are 0.493 mm, 0.451 mm and 0.452 mm for the 2D, 1D and single element transducers, respectively. The resolution in the moved-direction is improved with a moved transducer, but the contrast of the image is decreased.
More Related Videos
04:33Three-Dimensional Ultrasonic Needle Tip Tracking with a Fiber-Optic Ultrasound Receiver
Published on: August 21, 2018
09:56Universal Hand-held Three-dimensional Optoacoustic Imaging Probe for Deep Tissue Human Angiography and Functional Preclinical Studies in Real Time
Published on: November 4, 2014
Related Concept Videos
Ultrasonography
During an ultrasonography procedure, a handheld device called...
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Imaging Studies II: Ultrasonography
Ultrasound I: Abdominal Ultrasonography
Abdominal ultrasonography, commonly known as abdominal ultrasound, is a vital, non-invasive medical imaging technique widely used in healthcare.
Procedure:
This diagnostic tool allows the clinician to visually inspect internal structures within the abdomen, including vital organs such as the liver, gallbladder, pancreas, kidneys, and spleen.
The abdominal ultrasound process begins with applying a special gel to the patient's skin over the abdomen. This gel enhances the...