Related Experiment Video
Updated: Feb 18, 2026

Application of an Amplitude-integrated EEG Monitor Cerebral Function Monitor to Neonates
Published on: September 6, 2017
Clinical Manifestations and Amplitude-integrated Encephalogram in Neonates with Early-onset Epileptic Encephalopathy
Li-Li Liu1, Xin-Lin Hou1, Dan-Dan Zhang2
1Department of Pediatrics, Peking University First Hospital, Beijing 100034, China.
Insights
Early-onset epileptic encephalopathy (EOEE) in infants is associated with specific clinical and amplitude-integrated electroencephalogram (aEEG) patterns. Identifying these markers aids in early diagnosis and improved outcomes for neonatal seizures.
Area of Science:
- Neonatal Neurology
- Epileptology
- Neurodevelopmental Disorders
Background:
- Early-onset epileptic encephalopathy (EOEE) is a severe condition in infants leading to neurodevelopmental delays.
- Neonatal seizures are a critical indicator requiring thorough evaluation for potential EOEE development.
Purpose of the Study:
- To analyze clinical and amplitude-integrated electroencephalogram (aEEG) characteristics in infants with EOEE.
- To identify early diagnostic markers for EOEE in neonates to improve prognosis.
Main Methods:
- A cohort of 128 infants with neonatal seizures was followed for one year.
- Sixty-six neonates who developed EOEE were compared with 62 who did not (nEOEE) based on clinical and aEEG data.
Main Results:
- EOEE group showed higher incidence of daily seizures, multiple convulsion types, and more than two antiepileptic drugs (AEDs).
- Severely abnormal aEEG background and detection of multiple seizures by aEEG were independent risk factors for EOEE.
- Higher upper and lower margins of active sleep (AS) and quiet sleep (QS) were observed in the EOEE group, with AS upper margin showing high diagnostic accuracy.
Conclusions:
- Clinical indicators for EOEE include multiple AEDs, high seizure frequency, and diverse seizure types.
- aEEG findings like abnormal background, absence of cyclicity, and multiple seizure detections are significant predictors of EOEE.
Background:
The patients with early-onset epileptic encephalopathy (EOEE) suffer from neurodevelopmental delay. The aim of this study was to analyze the clinical manifestations and amplitude-integrated encephalogram (aEEG) characteristics of infants with EOEE with onset within the neonatal period, to make early diagnosis to improve the prognosis.
Methods:
One-hundred and twenty-eight patients with neonatal seizure were enrolled and followed up till 1 year old. Sixty-six neonates evolved into EOEE were as the EOEE group, the other 62 were as the non-EOEE (nEOEE) group. Then we compared the clinical and aEEG characteristics between the two groups to analyze the manifestations in neonates with EOEE.
Results:
Compared to the nEOEE group, the incidence of daily seizure attacks, more than two types of convulsions, more than two antiepileptic drugs (AEDs) application, severely abnormal aEEG background, absence of cyclicity, and more than two seizures detection were significantly higher in the EOEE group (P < 0.05) (97% vs. 54.8%; 30.3% vs. 14.5%; 97.0% vs. 25.4%; 39.4% vs. 3.2%; 57.6% vs. 9.7%; and 56% vs. 3.2%, respectively). Severely abnormal background pattern (odds ratio [OR] = 0.081, 95% confidence interval [CI]: 0.009-0.729, P = 0.025) and more than two seizures detection by aEEG (OR = 0.158, 95% CI: 0.043-0.576, P = 0.005) were the independent risk factors for the evolvement into EOEE. The upper and lower margins of active sleep (AS) and quiet sleep (QS) were significantly higher in EOEE group than those of the control group (P < 0.05) (34.3 ± 13.6 vs. 21.3 ± 6.4; 9.9 ± 3.7 vs. 6.7 ± 2.2; 41.2 ± 15.1 vs. 30.4 ± 11.4; and 11.9 ± 4.4 vs. 9.4 ± 4.0; unit: μV, respectively). AS upper margin was demonstrated a higher diagnostic specificity and sensitivity for EOEE than another three parameters according to the receiver operating characteristic curves; the area under the curve was 0.827.
Conclusions:
The clinical characteristics of the neonatal seizure which will evolve into EOEE were more than two AEDs application, high seizure frequency (daily attack), and more than two types of the seizure. Significant high voltage, severely abnormal background, absence of cyclicity, and more than two seizures detected on aEEG were the meaningful indicators to the prediction of EOEE.
Related Concept Videos
Epilepsy and Seizures: Overview
Various factors can trigger epilepsy, including genetic factors, brain damage, metabolic causes, and unknown etiology. Diagnosis of epilepsy involves electroencephalography (EEG), which...
Seizures: Classification
Seizures are typically classified into two main categories: focal and generalized seizures.
Focal Seizures
Focal seizures originate from specific regions of the brain. These seizures are further sub-classified into two types:

