The optimum sevoflurane concentration for supraglottic airway device Blockbuster™ insertion with spontaneous
Haixia Wang1, Xue Gao1, Wei Wei1
1Department of Anesthesiology, Beijing Friendship Hospital, Capital Medical University, Beijing, China.
Background:
Airway management of the obese patient presenting for surgery is more likely to be a challenging problem. Supraglottic airway device has been adopted as a bridge to connect ventilation and tracheal intubation in obese patients who would be suffered with difficult intubation. The optimum sevoflurane concentration for supraglottic airway device insertion allowing spontaneous breathing in 50% of obese patients (ED50) is not known. The purpose of this study was to determine the ED50 of sevoflurane for supraglottic airway device Blockbuster™ insertion with spontaneous breathing in obese patients requiring general anesthesia.
Methods:
Thirty elective obese patients (body mass index 30-50 kg/m2) undergoing bariatric surgery were recruited in this study. The predetermined target sevoflurane concentration (initiating at 2.5% with 0.5% as a step size) was sustained for >5 min using a modified Dixon's up-and-down method, and then the supraglottic airway device Blockbuster™ was inserted. The patient's response to supraglottic airway device insertion was classified as either 'movement' or 'no-movement'. The ED50 of sevoflurane were determined by calculating the midpoint concentration of crossover point from 'movement' or 'no-movement' response.
Results:
The ED50 of sevoflurane for supraglottic airway device Blockbuster™ insertion in obese patients calculated using up-and-down method were 2.50 ± 0.60%. The ED50 and ED95 (95% confidence interval) obtained by probit regression analysis were 2.35 (1.28-3.42) % and 4.03 (3.16-17.83) % for supraglottic airway device Blockbuster™ insertion, respectively.
Conclusion:
We conclude that the optimum end-tidal sevoflurane concentration required for the supraglottic airway device Blockbuster™ insertion allowing spontaneous breathing in 50% of obese patients (ED50) is 2.5 ± 0.6%.
Trial Registration:
Chinese Clinical Trial Registry, ChiCTR-IPR-16009071 , Registered on 24 August 2016.
More Related Videos
07:54Drug-Induced Sleep Endoscopy DISE with Target Controlled Infusion TCI and Bispectral Analysis in Obstructive Sleep Apnea
Published on: December 6, 2016
03:02Application of Dixon's Up-and-Down Design to Estimate the Minimum Alveolar Concentration of Sevoflurane in Rats with Refined Movement Classification
Published on: July 25, 2025
Related Concept Videos
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Inhalational Anesthetics: Overview
Cardiopulmonary Resuscitation II: ACLS Airway Management
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...