Background:
When tracheal intubation is difficult or unachievable before surgery or during an emergent resuscitation, this is a critical safety event. Consensus algorithms and airway devices have been introduced in hopes of reducing such occurrences. However, evidence of improved safety in clinical practice related to their introduction is lacking. Therefore, we selected a large perioperative database spanning 2002 to 2015 to look for changes in annual rates of difficult and failed tracheal intubation.
Methods:
Difficult (more than three attempts) and failed (unsuccessful, requiring awakening or surgical tracheostomy) intubation rates in patients 18 yr and older were compared between the early and late periods (pre- vs. post-January 2009) and by annual rate join-point analysis. Primary findings from a large, urban hospital were compared with combined observations from 15 smaller facilities.
Results:
Analysis of 421,581 procedures identified fourfold reductions in both event rates between the early and late periods (difficult: 6.6 of 1,000 vs. 1.6 of 1,000, P < 0.0001; failed: 0.2 of 1,000 vs. 0.06 of 1,000, P < 0.0001), with join-point analysis identifying two significant change points (2006, P = 0.02; 2010, P = 0.03) including a pre-2006 stable period, a steep drop between 2006 and 2010, and gradual decline after 2010. Data from 15 affiliated practices (442,428 procedures) demonstrated similar reductions.
Conclusions:
In this retrospective assessment spanning 14 yr (2002 to 2015), difficult and failed intubation rates by skilled providers declined significantly at both an urban hospital and a network of smaller affiliated practices. Further investigations are required to validate these findings in other data sets and more clearly identify factors associated with their occurrence as clues to future airway management advancements.
Visual Abstract:
An online visual overview is available for this article at http://links.lww.com/ALN/B635.
Related Concept Videos
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Tracheostomy Decannulation
Description of the Procedure
Decannulation refers to the permanent removal of the tracheostomy tube, signaling the resolution of the condition that initially necessitated the tracheostomy. The process requires a well-coordinated interplay between...
Tracheostomy Care I: Pre-procedural Steps
Required Equipment
The equipment necessary for tracheostomy care includes: