Accuracy of Invasive and Noninvasive Parameters for Diagnosing Ventilatory Overassistance During Pressure Support
Renata Pletsch-Assuncao1, Mayra Caleffi Pereira1, Jeferson George Ferreira1,2
1Pulmonary Division, Heart Institute (InCor), Hospital das Clínicas, Faculdade de Medicina da Universidade de São Paulo, São Paulo, Brazil.
Objective:
Evaluate the accuracy of criteria for diagnosing pressure overassistance during pressure support ventilation.
Design:
Prospective clinical study.
Setting:
Medical-surgical ICU.
Patients:
Adults under mechanical ventilation for 48 hours or more using pressure support ventilation and without any sedative for 6 hours or more. Overassistance was defined as the occurrence of work of breathing less than 0.3 J/L or 10% or more of ineffective inspiratory effort. Two alternative overassistance definitions were based on the occurrence of inspiratory esophageal pressure-time product of less than 50 cm H2O s/min or esophageal occlusion pressure of less than 1.5 cm H2O.
Interventions:
The pressure support was set to 20 cm H2O and decreased in 3-cm H2O steps down to 2 cm H2O.
Measurements And Main Results:
The following parameters were evaluated to diagnose overassistance: respiratory rate, tidal volume, minute ventilation, peripheral arterial oxygen saturation, rapid shallow breathing index, heart rate, mean arterial pressure, change in esophageal pressure during inspiration, and esophageal and airway occlusion pressure. In all definitions, the respiratory rate had the greatest accuracy for diagnosing overassistance (receiver operating characteristic area = 0.92; 0.91 and 0.76 for work of breathing, pressure-time product and esophageal occlusion pressure in definition, respectively) and always with a cutoff of 17 incursions per minute. In all definitions, a respiratory rate of less than or equal to 12 confirmed overassistance (100% specificity), whereas a respiratory rate of greater than or equal to 30 excluded overassistance (100% sensitivity).
Conclusion:
A respiratory rate of 17 breaths/min is the parameter with the greatest accuracy for diagnosing overassistance. Respiratory rates of less than or equal to 12 or greater than or equal to 30 are useful clinical references to confirm or exclude pressure support overassistance.
More Related Videos
Related Concept Videos
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Mechanical Ventilation I: Indication and Settings
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement: