Association of office and ambulatory blood pressure with blood lead in workers before occupational exposure
Wen-Yi Yang1, Ljupcho Efremov1, Blerim Mujaj1
1Research Unit Hypertension and Cardiovascular Epidemiology, KU Leuven Department of Cardiovascular Sciences, University of Leuven, Leuven, Belgium.
Abstract:
In view of decreasing lead exposure and guidelines endorsing ambulatory above office blood pressure (BP) measurement, we reassessed association of BP with blood lead (BL) in 236 newly employed men (mean age, 28.6 years) without previous lead exposure not treated for hypertension. Office BP was the mean of five auscultatory readings at one visit. Twenty-four-hour BP was recorded at 15- and 30-minute intervals during wakefulness and sleep. BL was determined by inductively coupled plasma mass spectrometry. Systolic/diastolic office BP averaged 120.0/80.7 mm Hg, and the 24-hour, awake, and asleep BP 125.5/73.6, 129.3/77.9, and 117.6/65.0 mm Hg, respectively. The geometric mean of blood lead was 4.5 μg/dL (interquartile range, 2.60-9.15 μg/dL). In multivariable-adjusted analyses, effect sizes associated with BL doubling were 0.79/0.87 mm Hg (P = .11/.043) for office BP and 0.29/-0.25, 0.60/-0.10, and -0.40/-0.43 mm Hg for 24-hour, awake, and asleep BP (P ≥ .33). Neither office nor 24-hour ambulatory hypertension was related to BL (P ≥ .14). A clinically relevant white coat effect (WCE; office minus awake BP, ≥20/≥10 mm Hg) was attributable to exceeding the systolic or diastolic threshold in 1 and 45 workers, respectively. With BL doubling, the systolic/diastolic WCE increased by 0.20/0.97 mm Hg (P = .57/.046). Accounting for the presence of a diastolic WCE, reduced the association size of office diastolic BP with BL to 0.39 mm Hg (95% confidence interval, -0.20 to 1.33; P = .15). In conclusion, a cross-sectional analysis of newly hired workers before lead exposure identified the WCE as confounder of the association between office BP and BL and did not reveal any association between ambulatory BP and BL.
More Related Videos
09:33Visualizing Field Data Collection Procedures of Exposure and Biomarker Assessments for the Household Air Pollution Intervention Network Trial in India
Published on: December 23, 2022
05:51Measuring the Carotid to Femoral Pulse Wave Velocity Cf-PWV to Evaluate Arterial Stiffness
Published on: May 3, 2018
Related Concept Videos
Pre-Procedural Guidelines for Assessing Blood Pressure
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Blood Pressure
The average BP in an adult is typically around 120/80 mmHg (millimeters of mercury). In this measurement, the numerator (120) indicates the systolic pressure, which is the pressure in the arteries during the contraction of the heart's ventricles as blood is expelled. The denominator (80) represents the...
Blood Pressure
Measurement of Blood Pressure