Related Experiment Video
Updated: Feb 17, 2026

Imaging of the Microstructural Failure Mechanism in the Human Hip
Published on: September 29, 2023
Differences in Trabecular Microarchitecture and Simplified Boundary Conditions Limit the Accuracy of Quantitative
Amira I Hussein1, Daniel T Louzeiro2, Ginu U Unnikrishnan2
1Department of Mechanical Engineering, Boston University, 110 Cummington Mall, Boston, MA 02215 e-mail: .
Abstract:
Vertebral fractures are common in the elderly, but efforts to reduce their incidence have been hampered by incomplete understanding of the failure processes that are involved. This study's goal was to elucidate failure processes in the lumbar vertebra and to assess the accuracy of quantitative computed tomography (QCT)-based finite element (FE) simulations of these processes. Following QCT scanning, spine segments (n = 27) consisting of L1 with adjacent intervertebral disks and neighboring endplates of T12 and L2 were compressed axially in a stepwise manner. A microcomputed tomography scan was performed at each loading step. The resulting time-lapse series of images was analyzed using digital volume correlation (DVC) to quantify deformations throughout the vertebral body. While some diversity among vertebrae was observed on how these deformations progressed, common features were large strains that developed progressively in the superior third and, concomitantly, in the midtransverse plane, in a manner that was associated with spatial variations in microstructural parameters such as connectivity density. Results of FE simulations corresponded qualitatively to the measured failure patterns when boundary conditions were derived from DVC displacements at the endplate. However, quantitative correspondence was often poor, particularly when boundary conditions were simplified to uniform compressive loading. These findings suggest that variations in trabecular microstructure are one cause of the differences in failure patterns among vertebrae and that both the lack of incorporation of these variations into QCT-based FE models and the oversimplification of boundary conditions limit the accuracy of these models in simulating vertebral failure.
More Related Videos
07:12Semiautomated Longitudinal Microcomputed Tomography-based Quantitative Structural Analysis of a Nude Rat Osteoporosis-related Vertebral Fracture Model
Published on: September 28, 2017
08:04Proximal Cadaveric Femur Preparation for Fracture Strength Testing and Quantitative CT-based Finite Element Analysis
Published on: March 11, 2017