Related Experiment Video
Updated: Feb 17, 2026

Use of an Integrated Low-Flow Anesthetic Vaporizer, Ventilator, and Physiological Monitoring System for Rodents
Published on: July 9, 2020
Changing Default Ventilator Settings on Anesthesia Machines Improves Adherence to Lung-Protective Ventilation
Sunny S Chiao1, Douglas A Colquhoun2, Bhiken I Naik1,3
1From the Department of Anesthesiology, University of Virginia, Charlottesville, Virginia.
Abstract:
Perioperative lung-protective ventilation (LPV) can reduce perioperative pulmonary morbidity. We hypothesized that modifying default anesthesia machine ventilator settings would increase the use of intraoperative LPV. Default tidal volume settings on our anesthesia machines were decreased from 600 to 400 mL, and default positive end-expiratory pressure was increased from 0 to 5 cm H2O. This modification increased mean positive end-expiratory pressure from 3.1 to 5.0 cm H2O and decreased mean tidal volume from 8.2 to 6.7 mL/kg predicted body weight. Notably, increased adherence to LPV from 1.6% to 23.0% occurred quickly with the rate of increase more than doubling from 1.8% to 3.9% per year.
Related Concept Videos
Mechanical Ventilation I: Indication and Settings
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Cardiopulmonary Resuscitation II: ACLS Airway Management
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes: