X-ray angiography perfusion imaging with an intra-arterial injection: comparative study with 15O-gas/water positron
Katsunori Asai1, Hajime Nakamura1, Tadashi Watabe2
1Department of Neurosurgery, Osaka University Graduate School of Medicine, Suita, Osaka, Japan.
Background:
X-ray angiography perfusion (XAP) is a perfusion imaging technique based on conventional DSA.
Objective:
In this study, we aimed to validate parameters derived from XAP by comparing them with 15O-gas/water positron emission tomography (PET), using data from patients with chronic ischemic cerebrovascular disease.
Methods:
18 consecutive patients were included. XAP was performed with intra-arterial infusion of contrast media, and a time-density curve was constructed for each cerebral hemisphere. From the curves, the relative values of mean transit time (rMTT) and wash-in rate (rWiR) were obtained by dividing the values of the right hemisphere by those of the left hemisphere. These were then compared with the relative values of cerebral blood flow (rCBF) and rMTT calculated from the PET data.
Results:
XAP rWiR correlated strongly with PET rCBF (r=0.86, P<0.0001). rMTT measurements from the two modalities were also strongly correlated (r=0.85, P<0.0001). Bland-Altman analysis revealed a bias of 0.14±0.18 (95% limits of agreement -0.22 to 0.51) for PET rCBF versus XAP rWiR, and 0.016±0.093 (95% limits of agreement -0.17 to 0.20) for rMTT between the two modalities.
Conclusions:
The relative values obtained from XAP were validated across a population of patients with chronic ischemic cerebrovascular disease.
More Related Videos
10:02Quantification of Atherosclerotic Plaque Activity and Vascular Inflammation using [18-F] Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography FDG-PET/CT
Published on: May 2, 2012
10:21Continuous Blood Sampling in Small Animal Positron Emission Tomography/Computed Tomography Enables the Measurement of the Arterial Input Function
Published on: August 8, 2019
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies VII: Vascular Imaging
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...