Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Digital Image Correlation-Based Bolt Preload Monitoring.

Sensors (Basel, Switzerland)·2026
Same author

Bone Marrow Mesenchymal Stem Cell Extracellular Vesicle-derived <i>miR-27b- 3p</i> activates the Wnt/Î’-catenin Pathway by Targeting SMAD4 and Aggravates Hepatic Ischemia-reperfusion Injury.

Current stem cell research & therapy·2023
Same author

BMSC-exosomes miR-25-3p Regulates the p53 Signaling Pathway Through PTEN to Inhibit Cell Apoptosis and Ameliorate Liver Ischemia‒reperfusion Injury.

Stem cell reviews and reports·2023
Same author

Deflection Estimation of Truss Structures Using Inverse Finite Element Method.

Sensors (Basel, Switzerland)·2023
Same author

Bayesian-Inference Embedded Spline-Kerneled Chirplet Transform for Spectrum-Aware Motion Magnification.

Sensors (Basel, Switzerland)·2022
Same author

Effect of Electrical Impedance Tomography-Guided Early Mobilization in Patients After Major Upper Abdominal Surgery: Protocol for a Prospective Cohort Study.

Frontiers in medicine·2021

Related Experiment Video

Updated: Feb 17, 2026

Investigating the Potential of Singly Curved Thin Piezoelectric Transducers for Energy Harvesting and Structural Health Monitoring
07:02

Investigating the Potential of Singly Curved Thin Piezoelectric Transducers for Energy Harvesting and Structural Health Monitoring

Published on: November 14, 2025

922

Dynamic Modelling of Embeddable Piezoceramic Transducers.

Linsheng Huo1, Xu Li2, Hongnan Li3,4

  • 1Key Laboratory of Coastal and Offshore Engineering, Dalian University of Technology, Dalian 116024, China. lshuo@dlut.edu.cn.

Sensors (Basel, Switzerland)
|December 6, 2017
PubMed
Summary
This summary is machine-generated.

This study models embeddable Lead Zirconate Titanate (PZT) transducers for structural health monitoring. Findings reveal how protective layers and excitation frequency impact PZT transducer performance, aiding in specialized transducer design.

Keywords:
Lead Zirconate Titanate (PZT) transducersdynamic model of PZT transducerseffect of protecting layereffect of waterproof layerembeddable PZT transducer

More Related Videos

Fabrication and Characterization of Thickness Mode Piezoelectric Devices for Atomization and Acoustofluidics
10:39

Fabrication and Characterization of Thickness Mode Piezoelectric Devices for Atomization and Acoustofluidics

Published on: August 5, 2020

7.5K
A Polymer-based Piezoelectric Vibration Energy Harvester with a 3D Meshed-Core Structure
09:51

A Polymer-based Piezoelectric Vibration Energy Harvester with a 3D Meshed-Core Structure

Published on: February 20, 2019

26.0K

Related Experiment Videos

Last Updated: Feb 17, 2026

Investigating the Potential of Singly Curved Thin Piezoelectric Transducers for Energy Harvesting and Structural Health Monitoring
07:02

Investigating the Potential of Singly Curved Thin Piezoelectric Transducers for Energy Harvesting and Structural Health Monitoring

Published on: November 14, 2025

922
Fabrication and Characterization of Thickness Mode Piezoelectric Devices for Atomization and Acoustofluidics
10:39

Fabrication and Characterization of Thickness Mode Piezoelectric Devices for Atomization and Acoustofluidics

Published on: August 5, 2020

7.5K
A Polymer-based Piezoelectric Vibration Energy Harvester with a 3D Meshed-Core Structure
09:51

A Polymer-based Piezoelectric Vibration Energy Harvester with a 3D Meshed-Core Structure

Published on: February 20, 2019

26.0K

Area of Science:

  • Materials Science
  • Structural Engineering
  • Mechanical Engineering

Background:

  • Embedded Lead Zirconate Titanate (PZT) transducers are crucial for concrete structure health monitoring.
  • Existing research highlights the need for robust transducer designs that account for environmental factors.

Purpose of the Study:

  • To develop and validate a dynamic model for embeddable PZT transducers, including waterproof and protective layers.
  • To analyze the influence of various material and thickness parameters on transducer dynamic properties.
  • To provide a scientific foundation for designing PZT transducers with tailored functionalities.

Main Methods:

  • Development of a dynamic model for embeddable PZT transducers.
  • Verification of the model using finite-element method (FEM) simulations.
  • Experimental validation through dynamic stress transfer tests.

Main Results:

  • The model accurately predicts transducer behavior under varying conditions.
  • Excitation frequency significantly impacts stress transfer amplitude and phase.
  • Natural frequency is sensitive to the material properties and thickness of waterproof and protective layers.

Conclusions:

  • The dynamic model provides insights into factors affecting embeddable PZT transducer performance.
  • Understanding these factors is essential for optimizing transducer design for specific applications.
  • This research supports the development of advanced PZT transducers for structural health monitoring.