Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Physical Methods for Controlling Microbial Growth: Radiation and Filtration01:26

Physical Methods for Controlling Microbial Growth: Radiation and Filtration

1.2K
Radiation and filtration are essential tools for microbial control, targeting microorganisms through distinct mechanisms. Radiation eliminates microbes by damaging their DNA, either killing them or inhibiting their growth. Based on wavelength, radiation is classified into two types: nonionizing and ionizing radiation.Non-ionizing radiation, such as UV radiation (200–400 nm), is absorbed by DNA, causing defects that effectively disinfect surfaces, air, and water, including safety cabinets.
1.2K
Methods of Sterilization I: Physical Methods01:29

Methods of Sterilization I: Physical Methods

23.8K
As used in a healthcare facility, sterilization destroys all microorganisms through physical or chemical methods. The physical method includes steam, dry heat, boiling water, and radiation.
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
23.8K
Methods of Sterilization II: Chemical Methods01:30

Methods of Sterilization II: Chemical Methods

9.2K
In healthcare, the chemical method of sterilization uses chemical sterilants to treat surgical instruments and medical supplies to help prevent the transmission of infectious pathogens to patients. Due to heat sensitivity, most medical supplies and equipment should not be exposed to high temperatures. These parts include rubber, plastic, glass, and other similar elements.
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
9.2K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Influence of food groups on plasma total homocysteine for specific MTHFR C677T genotypes in Chinese population.

Molecular nutrition & food research·2016
Same author

NIR Light Propulsive Janus-like Nanohybrids for Enhanced Photothermal Tumor Therapy.

Small (Weinheim an der Bergstrasse, Germany)·2016
Same author

Smart Hydrogels with Inhomogeneous Structures Assembled Using Nanoclay-Cross-Linked Hydrogel Subunits as Building Blocks.

ACS applied materials & interfaces·2016
Same author

Synergy between von Hippel-Lindau and P53 contributes to chemosensitivity of clear cell renal cell carcinoma.

Molecular medicine reports·2016
Same author

Aerobic Degradation of Sulfadiazine by Arthrobacter spp.: Kinetics, Pathways, and Genomic Characterization.

Environmental science & technology·2016
Same author

Downregulation of ClC-3 in dorsal root ganglia neurons contributes to mechanical hypersensitivity following peripheral nerve injury.

Neuropharmacology·2016

Related Experiment Video

Updated: Feb 17, 2026

Proof-of-Concept for Gas-Entrapping Membranes Derived from Water-Loving SiO2/Si/SiO2 Wafers for Green Desalination
09:39

Proof-of-Concept for Gas-Entrapping Membranes Derived from Water-Loving SiO2/Si/SiO2 Wafers for Green Desalination

Published on: March 1, 2020

7.9K

Floating rGO-based black membranes for solar driven sterilization.

Yao Zhang1, Dengwu Zhao, Fan Yu

  • 1State Key Laboratory of Metal Matrix Composites, School of Materials Science and Engineering, Shanghai Jiao Tong University, 800 Dongchuan Rd, Shanghai, 200240, P. R. China. dengtao@sjtu.edu.cn chengyi2013@sjtu.edu.cn.

Nanoscale
|December 6, 2017
PubMed
Summary
This summary is machine-generated.

A novel solar steam sterilization method uses interfacial evaporation for efficient, high-temperature steam generation. This low-cost approach offers a sustainable solution for sterilization in areas lacking electricity.

More Related Videos

Preparation of Light-responsive Membranes by a Combined Surface Grafting and Postmodification Process
12:00

Preparation of Light-responsive Membranes by a Combined Surface Grafting and Postmodification Process

Published on: March 21, 2014

12.3K
The Floating Lab: Standard Operational Procedure for Collecting and Filtering Seawater Samples from Operating Ferries for Environmental DNA Analysis
06:22

The Floating Lab: Standard Operational Procedure for Collecting and Filtering Seawater Samples from Operating Ferries for Environmental DNA Analysis

Published on: August 1, 2025

1.2K

Related Experiment Videos

Last Updated: Feb 17, 2026

Proof-of-Concept for Gas-Entrapping Membranes Derived from Water-Loving SiO2/Si/SiO2 Wafers for Green Desalination
09:39

Proof-of-Concept for Gas-Entrapping Membranes Derived from Water-Loving SiO2/Si/SiO2 Wafers for Green Desalination

Published on: March 1, 2020

7.9K
Preparation of Light-responsive Membranes by a Combined Surface Grafting and Postmodification Process
12:00

Preparation of Light-responsive Membranes by a Combined Surface Grafting and Postmodification Process

Published on: March 21, 2014

12.3K
The Floating Lab: Standard Operational Procedure for Collecting and Filtering Seawater Samples from Operating Ferries for Environmental DNA Analysis
06:22

The Floating Lab: Standard Operational Procedure for Collecting and Filtering Seawater Samples from Operating Ferries for Environmental DNA Analysis

Published on: August 1, 2025

1.2K

Area of Science:

  • Materials Science
  • Renewable Energy
  • Sterilization Technology

Background:

  • Conventional solar autoclaves require complex designs to manage high steam pressure.
  • Sterilization is crucial in healthcare and research, particularly in resource-limited settings.
  • Developing efficient, low-cost solar-powered sterilization methods is an ongoing challenge.

Purpose of the Study:

  • To introduce a new, simplified solar steam sterilization approach.
  • To demonstrate the efficacy of interfacial evaporation for high-temperature steam generation.
  • To provide a sustainable sterilization solution for off-grid or low-resource areas.

Main Methods:

  • A solar-driven interfacial evaporation system was designed using a reduced graphene oxide/polytetrafluoroethylene composite membrane.
  • The membrane floats at the water/air interface, acting as a light-to-heat converter.
  • A prototype sterilization device was constructed and tested using chemical and biological indicators.

Main Results:

  • The system generated steam exceeding 120 °C through localized heating at the water/air interface.
  • The composite membrane efficiently converted solar energy into heat for steam production.
  • Successful sterilization was confirmed via chemical and biological tests, validating the device's performance.

Conclusions:

  • Interfacial solar-driven evaporation offers a simplified and effective method for steam sterilization.
  • This technology bypasses the need for high-pressure components found in conventional solar autoclaves.
  • The approach presents a promising, low-cost, and sustainable sterilization solution for areas with abundant solar radiation and limited electricity.