Related Experiment Video
Updated: Jan 19, 2026

In Vitro Evaluation of The Effects Of Er,Cr:YSGG and Diode Lasers Used on Titanium Cylinder
Published on: June 6, 2025
Comparative study between laser and conventional techniques for class V cavity preparation in gamma-irradiated teeth
Amr H M Rasmy1, Tarek A Harhash2, Rami M S Ghali3
1Egyptian Atomic Energy Authority, National Centre for Radiation Research and Technology (NCRRT), Health Radiation Research Department, Cairo, Egypt.
Objective:
The purpose of this study was to compare laser with conventional techniques in class V cavity preparation in gamma-irradiated teeth.
Methods:
Forty extracted human teeth with no carious lesions were used for this study and were divided into two main groups: Group I (n = 20) was not subjected to gamma radiation (control) and Group II (n=20) was subjected to gamma radiation of 60 Gray. Standard class V preparation was performed in buccal and lingual sides of each tooth in both groups. Buccal surfaces were prepared by the Er,Cr:YSGG laser (Waterlase iPlus) 2780 nm, using the gold handpiece with MZ10 Tip in non-contact and the "H" mode, following parameters of cavity preparation - power 6 W, frequency 50 Hz, 90% water and 70% air, then shifting to surface treatment laser parameters - power 4.5 W, frequency 50 Hz, 80% water and 50% air. Lingual surfaces were prepared by the conventional high-speed turbine using round diamond bur. Teeth were then sectioned mesio-distally, resulting in 80 specimens: 40 of which were buccal laser-treated (20 control and 20 gamma-irradiated specimens) and 40 were lingual conventional high-speed bur specimens (20 control and 20 gamma-irradiated specimens).
Results:
Microleakage analysis revealed higher scores in both gamma groups compared with control groups. Chi-square test revealed no significant difference between both control groups and gamma groups (p=1, 0.819, respectively). A significant difference was revealed between all 4 groups (p=0.00018).
Conclusion:
Both laser and conventional high-speed turbine bur show good bond strength in control (non-gamma) group, while microleakage is evident in gamma group, indicating that gamma radiation had a dramatic negative effect on the bond strength in both laser and bur-treated teeth.