Related Experiment Video
Updated: Feb 17, 2026

Tracking the Mammary Architectural Features and Detecting Breast Cancer with Magnetic Resonance Diffusion Tensor Imaging
Published on: December 15, 2014
Feasibility of breast MRI after sentinel procedure for breast cancer with superparamagnetic tracers
Benedict Krischer1, Serafino Forte2, Tilo Niemann2
1Department of Gynecology, Breast Center, Kantonsspital Baden, Switzerland.
Rationale:
The gold standard for detection of axillary sentinel lymph nodes uses injection of a radioisotope (99Tc Nanocoll). As an alternative to this method, a magnetometer detecting the superparamagnetic tracer Sienna+® can be applied for detection of sentinel lymph nodes. The goal of this study was to determine whether interpretation of breast MRI is impaired by Sienna+® tracer residues in the operated breast and axillary lymph nodes after a sentinel procedure using this tracer.
Patients And Methods:
34 patients who received the Sienna+® tracer for marking the sentinel node were invited to undergo a follow-up breast MRI. Native MR images were obtained from breast and axilla. The breast MRIs were evaluated by two independent breast radiologists for Sienna+® tracer related artefacts and for the degree of impairment of the MR imaging.
Results:
24 of the 34 invited patients took part in this study. The mean time since injection of Sienna+® was 42 months (40.6-45.4 months). Two patients had bilateral surgery with injections in both breasts, leading to a total of 26 separate cases. One case had to be excluded due to breathing artefacts. In 10 cases (40%), impaired imaging was found. In three cases (12%), the MRI scan reading was impossible due to Sienna+® tracer residues, the other 12 cases (48%) showed no restriction. In the subgroup of patients treated with breast conserving surgery, tracer residue artefacts were found in 13 of 17 patients (76.5%).
Conclusion:
To our knowledge, in this study for the first time MR feasibility after Sienna injection was investigated. Sienna+® impaired breast MRI after a mean follow-up time of 42 months in half of the cases. Further research is needed to investigate time and field-strength dependency of tracer detectability as well as the diagnostic impact of these artifacts on contrast-enhanced imaging in a clinical setting.
Related Concept Videos
Magnetic Resonance Imaging
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies IV: Magnetic Resonance Imaging
Imaging Studies for Cardiovascular System IV: CMRI
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...