Related Experiment Video
Updated: Feb 17, 2026

Fizzy Extraction of Volatile Organic Compounds Combined with Atmospheric Pressure Chemical Ionization Quadrupole Mass Spectrometry
Published on: July 14, 2017
Vacuum-Ultraviolet-Excited and CH2Cl2/H2O-Amplified Ionization-Coupled Mass Spectrometry for Oxygenated Organics
Bo Yang1,2, Haixu Zhang1,2, Jinian Shu1,2
1State Key Laboratory of Environment Simulation and Pollution Control, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences , Beijing 100085, China.
Abstract:
The mass spectrometry analysis of oxygenated volatile organic compounds (OVOCs) remains challenging due to their limited ionization efficiencies. In this study, we surprisingly found that, under vacuum-UV (VUV) excitation, a gaseous mixture of CH2Cl2/H2O/analyte (OVOCs) in N2 buffer generated large amounts of H3O+ and protonated analyte even when the photon energy was lower than the ionization energy of the neutral species involved. In contrast to those obtained with VUV photoionization alone, the signal intensities of oxygenated organics can be amplified by more than 3 orders of magnitude. The isotope tracing experiment revealed that the proton donor is water, and the dependence of the signal intensities on the VUV photon intensities verified that the reaction was a single-photon process. The observed ionization process is assigned as an undocumented chemi-ionization reaction in which a complex formed from the ion-pair state CH2Cl2*, H2O, and analyte and then autoionized to produce the protonated analyte with the aid of the reorganization energy released from the formation of CH2O and HCl. Essentially, here we present an efficient chemi-ionization method for the direct protonation of oxygenated organics. By the method, the mass spectrometric sensitivities toward acetic acid, ethanol, aldehyde, diethyl ether, and acetone were determined to be 224 ± 17, 245 ± 5, 477 ± 14, 679 ± 11, and 684 ± 6 counts pptv-1, respectively, in 10 s acquisition time. In addition, the present ionization process provides a new method for the generation of a high-intensity H3O+ source (∼1011 ions s-1, measured by ion current) by which general organics can be indirectly protonated via a conventional proton-transfer reaction. These results open new aspects of chemi-ionization reactions and offer new technological applications that have the potential to greatly improve mass spectrometry sensitivity for detecting trace gaseous organics.
More Related Videos
05:48Analysis of Volatile and Oxidation Sensitive Compounds Using a Cold Inlet System and Electron Impact Mass Spectrometry
Published on: September 5, 2014
09:38Single-throughput Complementary High-resolution Analytical Techniques for Characterizing Complex Natural Organic Matter Mixtures
Published on: January 7, 2019
Related Concept Videos
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Chemical Ionization (CI) Mass Spectrometry
Mass Spectrometry: Alcohol Fragmentation
Atomic Absorption Spectroscopy: Atomization Methods
Mass Spectrometry: Aromatic Compound Fragmentation
Mass Spectrometers