Related Experiment Video
Updated: Feb 17, 2026

Author Spotlight: Assessing the Reliability of Doppler Ultrasound in Measuring Leg Blood Flow
Published on: December 15, 2023
Reliability of oscillometric central blood pressure responses to lower limb resistance exercise
Simon Fryer1, Keeron Stone1, Tabitha Dickson1
1School of Sport and Exercise, University of Gloucestershire, Gloucestershire, UK.
Background And Aims:
Although it is well known that resistance training (RT) is beneficial for patients suffering from a variety of cardiovascular diseases, it remains underutilized as a rehabilitation tool as there is no reliable way to monitor the additional stress placed on the central organs. The current study aimed to determine between-day reliability of central haemodynamic indices using oscillometric pulse wave analysis (PWA) during progressive sub-maximal RT.
Methods:
Nineteen healthy young males were tested on 3 different mornings in a fasted state. Central hemodynamic variables including augmentation index (AIx), AIx normalized to a heart rate of 75 beats per minute (AIx@75), central systolic blood pressure (cSBP), forwards (Pf) and backwards (Pb) wave reflection were determined at rest, as well as during leg extension RT at 10, 15 and 20% of maximal volitional contraction (MVC), and following 1 min and 5 min passive recovery.
Results:
During RT at 10, 15 and 20% MVC, the intraclass correlation coefficient (ICC) values for AIx@75 (0.76-0.9), cSBP (0.74-0.78), Pf (0.75-0.82) and Pb (0.75-0.83) exceeded the criteria (0.75) for excellent reliability. During the 5 min recovery, the ICC values for AIx@75 (0.87-0.87), cSBP (0.69-0.7), Pf (0.63-0.67) and Pb (0.63-0.66) indicated good to excellent reliability.
Conclusions:
Clinically meaningful changes in central hemodynamic indices can be obtained during resistance training using oscillometric PWA devices. This technology holds potential for advancing resistance training prescription guidelines for patients with overt cardiovascular diseases.
More Related Videos
14:09Tilt Testing with Combined Lower Body Negative Pressure: a "Gold Standard" for Measuring Orthostatic Tolerance
Published on: March 21, 2013
04:44Author Spotlight: Enhancing Vascular Function and Physical Capacity in Cardiovascular Disease Through Novel Interventions and NIRS Technology
Published on: March 22, 2024
Related Concept Videos
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessing Blood pressure in the Leg
Preparation:
Pre-Procedural Guidelines for Assessing Blood Pressure
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessment of blood pressure in brachial artery(two-step method)
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure: