Related Experiment Video
Updated: Feb 17, 2026

Isolation of F1-ATPase from the Parasitic Protist Trypanosoma brucei
Published on: January 22, 2019
Functional characterization of the Ca2+-ATPase SMA1 from Schistosoma mansoni
Xavier Maréchal1,2,3, Ricardo De Mendonça4, Roger Miras1,2,3
1Université Grenoble Alpes, F-38054 Grenoble, France.
Abstract:
Schistosoma mansoni is a parasite that causes bilharzia, a neglected tropical disease affecting hundreds of millions of people each year worldwide. In 2012, S. mansoni had been identified as the only invertebrate possessing two SERCA-type Ca2+-ATPases, SMA1 and SMA2. However, our analysis of recent genomic data shows that the presence of two SERCA pumps is rather frequent in parasitic flatworms. To understand the reasons of this redundancy in S. mansoni, we compared SMA1 and SMA2 at different levels. In terms of sequence and organization, the genes SMA1 and SMA2 are similar, suggesting that they might be the result of a duplication event. At the protein level, SMA1 and SMA2 only slightly differ in length and in the sequence of the nucleotide-binding domain. To get functional information on SMA1, we produced it in an active form in Saccharomyces cerevisiae, as previously done for SMA2. Using phosphorylation assays from ATP, we demonstrated that like SMA2, SMA1 bound calcium in a cooperative mode with an apparent affinity in the micromolar range. We also showed that SMA1 and SMA2 had close sensitivities to cyclopiazonic acid but different sensitivities to thapsigargin, two specific inhibitors of SERCA pumps. On the basis of transcriptomic data available in GeneDB, we hypothesize that SMA1 is a housekeeping Ca2+-ATPase, whereas SMA2 might be required in particular striated-like muscles like those present the tail of the cercariae, the infecting form of the parasite.
Related Concept Videos
ATP Synthase: Mechanism
ATP Synthase: Structure
ATP Driven Pumps II: P-type Pumps
A typical P-type pump has three cytosolic domains: nucleotide-binding (N), phosphorylation (P), and activator (A) domains. These domains are connected to the membrane-spanning helices by short amino acid segments. ATP hydrolysis and covalent phosphoenzyme intermediate formation are crucial parts of the catalytic cycle. At the highly...
Overview of Myosin Structure and Function
ATP Driven Pumps III: V-type Pumps
The peripheral or cytosolic V1 domain with eight subunits is involved in ATP hydrolysis. The integral or transmembrane V0 domain containing at least five subunits...
The Sarcomere
Each...