Lack of grading agreement among international hemostasis external quality assessment programs
John D Olson1, Ian Jennings2, Piet Meijer3
1Department of Pathology, University of Texas Health Science Center at San Antonio, San Antonio, Texas, USA.
Abstract:
: Laboratory quality programs rely on internal quality control and external quality assessment (EQA). EQA programs provide unknown specimens for the laboratory to test. The laboratory's result is compared with other (peer) laboratories performing the same test. EQA programs assign target values using a variety of methods statistical tools and performance assessment of 'pass' or 'fail' is made. EQA provider members of the international organization, external quality assurance in thrombosis and hemostasis, took part in a study to compare outcome of performance analysis using the same data set of laboratory results. Eleven EQA organizations using eight different analytical approaches participated. Data for a normal and prolonged activated partial thromboplastin time (aPTT) and a normal and reduced factor VIII (FVIII) from 218 laboratories were sent to the EQA providers who analyzed the data set using their method of evaluation for aPTT and FVIII, determining the performance for each laboratory record in the data set. Providers also summarized their statistical approach to assignment of target values and laboratory performance. Each laboratory record in the data set was graded pass/fail by all EQA providers for each of the four analytes. There was a lack of agreement of pass/fail grading among EQA programs. Discordance in the grading was 17.9 and 11% of normal and prolonged aPTT results, respectively, and 20.2 and 17.4% of normal and reduced FVIII results, respectively. All EQA programs in this study employed statistical methods compliant with the International Standardization Organization (ISO), ISO 13528, yet the evaluation of laboratory results for all four analytes showed remarkable grading discordance.
More Related Videos
08:44An In Vitro Hemodynamic Loop Model to Investigate the Hemocytocompatibility and Host Cell Activation of Vascular Medical Devices
Published on: August 21, 2020
09:41Hemocompatibility Testing of Blood-Contacting Implants in a Flow Loop Model Mimicking Human Blood Flow
Published on: March 5, 2020
Related Concept Videos
Disorders of Hemostasis
Thromboembolic Disorders
Two factors primarily cause thromboembolic conditions.
Extrinsic and Intrinsic Pathways of Hemostasis
The Extrinsic Pathway
The extrinsic pathway of coagulation is typically initiated by tissue damage that exposes blood to tissue factor (TF), a protein released by the damaged tissue cells outside the blood vessels—this interaction with TF triggers biochemical reactions involving specific clotting factors. The key player here is Factor VII, which...
Introduction to Hemostasis
The three phases of hemostasis involve many clotting factors present in plasma and several substances released by platelets and injured tissue cells. It is a fast, localized,...
Anticoagulant Drugs: Low-Molecular-Weight Heparins
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...