Related Experiment Video
Updated: Feb 17, 2026

Assessing the Accuracy of Fitness Smartwatch Data for Cardiovascular and Physical Activity Monitoring: A Validation Study in Digital Health
Published on: February 21, 2025
A validation study of Fitbit Charge 2™ compared with polysomnography in adults
Massimiliano de Zambotti1, Aimee Goldstone1, Stephanie Claudatos1
1a Center for Health Sciences , SRI International , Menlo Park , CA , USA.
Abstract:
We evaluated the performance of a consumer multi-sensory wristband (Fitbit Charge 2™), against polysomnography (PSG) in measuring sleep/wake state and sleep stage composition in healthy adults. In-lab PSG and Fitbit Charge 2™ data were obtained from a single overnight recording at the SRI Human Sleep Research Laboratory in 44 adults (19-61 years; 26 women; 25 Caucasian). Participants were screened to be free from mental and medical conditions. Presence of sleep disorders was evaluated with clinical PSG. PSG findings indicated periodic limb movement of sleep (PLMS, > 15/h) in nine participants, who were analyzed separately from the main group (n = 35). PSG and Fitbit Charge 2™ sleep data were compared using paired t-tests, Bland-Altman plots, and epoch-by-epoch (EBE) analysis. In the main group, Fitbit Charge 2™ showed 0.96 sensitivity (accuracy to detect sleep), 0.61 specificity (accuracy to detect wake), 0.81 accuracy in detecting N1+N2 sleep ("light sleep"), 0.49 accuracy in detecting N3 sleep ("deep sleep"), and 0.74 accuracy in detecting rapid-eye-movement (REM) sleep. Fitbit Charge 2™ significantly (p < 0.05) overestimated PSG TST by 9 min, N1+N2 sleep by 34 min, and underestimated PSG SOL by 4 min and N3 sleep by 24 min. PSG and Fitbit Charge 2™ outcomes did not differ for WASO and time spent in REM sleep. No more than two participants fell outside the Bland-Altman agreement limits for all sleep measures. Fitbit Charge 2™ correctly identified 82% of PSG-defined non-REM-REM sleep cycles across the night. Similar outcomes were found for the PLMS group. Fitbit Charge 2™ shows promise in detecting sleep-wake states and sleep stage composition relative to gold standard PSG, particularly in the estimation of REM sleep, but with limitations in N3 detection. Fitbit Charge 2™ accuracy and reliability need to be further investigated in different settings (at-home, multiple nights) and in different populations in which sleep composition is known to vary (adolescents, elderly, patients with sleep disorders).
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Sleep Apnea
The condition is more prevalent among...
Holter Monitor: 24-Hour Monitoring