Determination of halogenated flame retardants by GC-API-MS/MS and GC-EI-MS: a multi-compound multi-matrix method
Frank Neugebauer1, Annekatrin Dreyer2, Nina Lohmann1
1Eurofins GfA Lab Service GmbH, Neuländer Kamp 1a, 21079, Hamburg, Germany.
Abstract:
The extensive application of halogenated flame retardants has led to their widespread distribution in the environment. Recently, concerns emerged regarding their potential persistence, (bio)accumulation, and/or toxicity. Particularly halogenated flame retardants based on norbornene structures, like Dechlorane Plus as well as other brominated PBDE replacements, generically called emerging, novel, or alternative flame retardants, are in the focus of interest. A comprehensive analytical method for the determination of 21 halogenated flame retardants (HFRs) of different substance classes (dechloranes, brominated aromates, brominated ethers, cyclic BFR) in a broad variety of matrices (tree leaves, fish fillet, birds eggs, suspended particles) was developed in order to assess their environmental levels as well as temporal trends, especially for the use within environmental specimen banks (ESBs). In addition to the alternative HFRs, a set of 24 PBDEs were measured in the same samples, however using GC-EI-MS for detection. Samples were extracted using accelerated solvent extraction (ASE) with dichloromethane:hexane (exception: soxhlet extraction for suspended particles) followed by a multi column clean-up. Quantification was performed by API-GC-MS/MS as a modern, gentle, and sensitive technique for simultaneous detection of compounds throughout a wide range of masses and fragmentation characteristics (exception: PBDE detection using GC-EI-MS). With the exception of BDE 209, instrumental precisions of target compounds ranged from 1% to 16 % (at levels of 2 pg injection-1 for HFR, 20 pg injection-1 for DBDPE, 7-36 pg injection-1 for PBDEs). Interday precisions of the entire analytical method including extraction and clean-up were mostly below 25% for all validation matrices at spiked levels of 100 pg sample-1 for HFR (DBDPE: 1000 pg sample-1) and 1200-6000 pg sample-1 for PBDEs. The majority of analytes were investigated with expanded measurement uncertainties of less than 50%. Graphical abstract A new approach to HFR analysis in multiple environmental matrices.
More Related Videos
08:56Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry
Published on: November 22, 2024
05:20Avocado Sample Preparation Using the QuEChERS Method with Ammonium Formate for Pesticide Analysis
Published on: December 8, 2023
Related Concept Videos
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
High-Performance Liquid Chromatography: Types of Detectors