Related Experiment Video
Updated: Feb 17, 2026

The Supraclavicular Fossa Ultrasound View for Central Venous Catheter Placement and Catheter Change Over Guidewire
Published on: December 23, 2014
Chest Radiograph Measurement Technique Facilitates Accurate Bedside Peripherally Inserted Central Catheter Placement
Aishu Ramamurthi1,2, Jeffrey Forris Beecham Chick1, Rajiv N Srinivasa1
1Department of Radiology, Division of Vascular and Interventional Radiology, University of Michigan Medical Center, 1500 East Medical Center Drive, Ann Arbor, MI, 48109, USA.
Purpose:
To report the chest radiograph measurement technique for placing bedside peripherally inserted central catheters (PICCs).
Materials And Methods:
Two hundred and thirty-two consecutive pediatric patients, mean age of 56.3 months (range: 0-203 months), underwent PICC placement from January 2015 to May 2017 (28 months) with a total of 232 PICCs placed. Measurements were taken from the cavoatrial junction to clavicle, clavicle to medial margin of mid-humeral head, and medial margin of mid-humeral head to mid-humerus. The difference between total radiographic measured length and actual PICC length was then calculated, and the percent difference (from actual cut length) was recorded. An equivalence test was performed using the two, one-sided test method.
Results:
Mean ± standard deviation cavoatrial junction to clavicle length was 5.29 ± 2.20 cm (range: 2.1-12.6 cm). Mean clavicle to shoulder length was 8.20 ± 3.59 cm (range: 3.23-19.06 cm). Mean shoulder to mid-humerus length was 7.88 ± 3.87 cm (range: 2.01-16.8 cm). Mean total radiographic measured length was 21.37 ± 9.19 cm (range: 7.42-43.6 cm). Mean actual cut PICC length was 20.64 ± 8.72 cm (range: 8.5-44 cm). The mean difference between predicted, or total radiographic measured length, and actual cut PICC length was 0.73 ± 2.51 (range: - 5.42-8.60 cm). The mean percent difference was 4.07 ± 12.65% (range: - 23.84-47.80%). An equivalence test rejected the null hypothesis of the true percent difference greater/less than ± 6.67% with a p value of 0.002.
Conclusion:
The chest radiograph measurement technique is an accurate method to determine catheter length for PICC placement at bedside in the pediatric population.
More Related Videos
07:56Closed Chest Biventricular Pressure-Volume Loop Recordings with Admittance Catheters in a Porcine Model
Published on: May 18, 2021
08:22The Application of Point-of-Care Ultrasonography (POCUS) in the Management of Acute Respiratory Distress Syndrome (ARDS) in the Intensive Care Unit
Published on: December 12, 2025
Related Concept Videos
Cardiac Catheterization II: Right Heart Catheterization
Cardiac Catheterization III: Left Heart Catheterization
Parentral Nutrition: Centeral and Peripheral Parental Nutrition
PN can be administered through two primary routes:
1. Central Parenteral Nutrition (CPN):
CPN involves delivering a high concentration of nutrients through a large vein. This is typically achieved using a Peripherally Inserted Central Catheter (PICC) or,...
Radiological Investigation I: X-ray and CT
Cardiac Catheterization I: Pre-Procedure Overview
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...