Background:
The impact of postural changes on various electrocardiography (ECG) characteristics has only been assessed in a few small studies. This large prospective trial was conducted to confirm or refute preliminary data and add important results with immediate impact on daily clinical practice.
Methods:
ECGs in supine and upright position from 1028 patients were analyzed. Evaluation was made according to changes in T-wave vector and direction, ST-segment deviation, heart rate, QT interval and QTc interval was performed. Findings were correlated with the medical history of patients.
Results:
Positional change from supine to upright resulted in a significantly increased heart rate (8.05 ± 7.71 bpm) and a significantly increased QTc interval after Bazetts (18 ± 23.45 ms) and Fridericas (8.84 ± 17.30) formula. In the upright position significantly more T-waves turned negative (14.7%) than positive (5.7%). ST elevation was recorded in only 0.4% and ST depression in not more than 0.2% of all patients.
Conclusions:
The majority of the patients do not show significant morphological changes in their ECG by changing the body position from supine to upright. Changes of QTc time instead, are significant and the interval might be overestimated in upright. Therefore assessment of the QTc interval should strictly be done in a supine position.
More Related Videos
18:11A Research Method For Detecting Transient Myocardial Ischemia In Patients With Suspected Acute Coronary Syndrome Using Continuous ST-segment Analysis
Published on: December 28, 2012
14:09Tilt Testing with Combined Lower Body Negative Pressure: a "Gold Standard" for Measuring Orthostatic Tolerance
Published on: March 21, 2013
Related Concept Videos
Anatomical Positions
The body is upright, facing forward, and standing erect.
The feet are parallel and flat on the floor.
The arms are hanging by the...
Cardiac Action Potential
The cardiac action potential process involves a series of phases characterized by the movement of ions across the cardiac cell membranes, leading to the depolarization and repolarization of the cardiac myocytes.
Ionic Basis of Cardiac Action Potentials
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin...
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...