Related Experiment Video
Updated: Feb 16, 2026

Longitudinal Micro-Computed Tomography Image Analysis for User-Defined Region of Interest in Critical-Sized Bone Defects
Published on: June 24, 2025
A new method to locate the radial head "safe zone" on computed tomography axial views
1Department of orthopaedic surgery, Shanghai Jiaotong university affiliated Shanghai Sixth People's Hospital, 200233 P.R. Shanghai, China.
Purpose:
Direct location of the "safe zone" on a CT axial view is impossible because the radial head is circular in shape. Previous "safe zone" location methods are not appropriate if the physician is unable to visualize the actual radial head. This study aims to introduce a new method to locate the "safe zone" on CT.
Methods:
CT scans were performed on 20 intact cadaveric upper limbs from 20 different corpses in full pronation and supination. The DICOM-format raw data were then re-sliced and analyzed in Mimics 17.0 (Materialise, Belgium). The radial interosseous border (IB) is shaped like a droplet on the axial view; its axis was selected as our reference line (RL). A parallel line in the radial head axial slice was created, and its position relative to the "safe zone" was studied. Deviation in RL direction was evaluated.
Results:
Safe-zone scope was 114.41°±11.99. The rotation angle from the RL to the safe-zone's anterior and posterior border was 215.03°±5.99 and 100.62°±8.12, respectively. Rotation direction (clockwise or anti-clockwise) depended on relative radius-ulna position. The safe zone was located by determining these two borders. The reference line's direction was stable in the upper half of the IB; its distance to the radial head fovea was 77.33° mm±6.24.
Conclusions:
The radial head "safe zone" can be located on CT axial view based on the upper half of the IB using this new method. The method is clinically applicable to determine whether postoperative elbow malrotation results from plate impingement.
More Related Videos
10:23Author Spotlight: Three-Dimensional Cephalometric Landmark Annotation Demonstration on Human Cone Beam Computed Tomography Scans
Published on: September 8, 2023
05:49Author Spotlight: Advancing CBCT and Digital Dental Image Integration with AI-Assisted Digitization
Published on: February 23, 2024
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...