Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

The Y-to-Y Circuit01:19

The Y-to-Y Circuit

772
In a balanced four-wire wye-to-wye system, the arrangement involves wye-connected sinusoidal voltage sources and loads, connected through a neutral wire that links the neutral nodes of the source and load. The load impedance is connected across each phase of the load. The wye-connected source can be connected to the wye-connected load in four-wire and three-wire arrangements. A three-phase system is considered balanced when the load on each phase is equal, leading to uniform current flow and...
772
Fault Types01:18

Fault Types

437
When analyzing a single line-to-ground fault from phase A to ground at a three-phase bus, it is important to consider the fault impedance. This impedance is zero for a bolted fault, equal to the arc impedance for an arcing fault, and represents the total fault impedance for a transmission-line insulator flashover. To derive sequence and phase currents, fault conditions are translated from the phase domain to the sequence domain.
For line-to-line faults occurring between phases B and C, the...
437
Bus Impedance Matrix01:24

Bus Impedance Matrix

541
Calculating subtransient fault currents for three-phase faults in an N-bus power system involves using the positive-sequence network. When a three-phase short circuit occurs at a specific bus, the analysis uses the superposition method to evaluate two separate circuits.
In the first circuit, all machine voltage sources are short-circuited, leaving only the prefault voltage source at the fault location. The positive-sequence bus impedance matrix can be determined by solving the nodal equations,...
541
Inductance: Single-Phase And Three-Phase Line01:28

Inductance: Single-Phase And Three-Phase Line

649
Understanding the inductance of transmission lines is crucial for efficient design and operation in electrical power systems. This discussion delves into the inductance characteristics of single-phase two-wire and three-phase three-wire transmission lines with equal phase spacing.
Single-Phase Two-Wire Line:
A single-phase line consists of two solid cylindrical conductors, denoted as x and y. Each conductor carries phasor currents ix and iy, respectively. Given that the sum of these currents is...
649
Three-Phase Circuits01:22

Three-Phase Circuits

882
AC power distribution systems have three categories: single-phase, two-phase, and three-phase systems. The single-phase circuit, common in residential settings, typically employs a two-wire system connecting a single AC source to various loads. These circuits support standard household appliances operating at 120 volts (V) and 240 V, such as lamps, televisions, and microwaves. The first generators, Niagara Falls hydro plant installed in 1895, were two-phase and designed by Nikola Tesla. The...
882
The Delta-to-Delta Circuit01:17

The Delta-to-Delta Circuit

1.2K
In a delta-delta configuration, the source and the load are connected in a delta manner, forming a closed loop that divides the network into three distinct phases. This configuration makes the phase voltages identical to line voltages. Assuming the sources are in positive sequence, the phase voltages can be expressed directly without having a neutral wire.
1.2K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Dynamic Angiography Demonstrating Discogenic Bow Hunter Syndrome.

Stroke·2026
Same author

Refractory and Challenging Thrombectomy.

Seminars in interventional radiology·2026
Same author

Pathologically Confirmed Symptomatic Carotid Webs: Histopathological Features and Long-Term Surgical Outcomes.

Neurosurgery·2026
Same author

Effect of Acute Intracranial Stenting in Patients With Successful Reperfusion Following Large-Vessel Occlusion Secondary to Intracranial Atherosclerosis: Secondary Analyses of the RESCUE-ICAS Study.

Stroke (Hoboken, N.J.)·2026
Same author

Misleading Morphology: Histological Diagnosis Reveals Atherosclerotic Plaque Mimicking Carotid Web.

Stroke (Hoboken, N.J.)·2026
Same author

Emergence of Venous Stenosis as the Dominant Cause of Pulsatile Tinnitus.

Stroke (Hoboken, N.J.)·2026
Same journal

Neuroradiology Leads NIH Funding Among Clinician Diagnostic Radiologists: A 14-Year National Analysis.

AJNR. American journal of neuroradiology·2026
Same journal

Neutral Cervical Spine MRI is Not Enough: The Critical Role of Flexion Imaging in Hirayama disease in Pediatric Patients.

AJNR. American journal of neuroradiology·2026
Same journal

CT Evaluation of Osseous Trauma at the Craniocervical Junction: A Pattern-Based Overview.

AJNR. American journal of neuroradiology·2026
Same journal

Comprehensive Structural MRI Phenotyping in <i>Oligophrenin 1-</i>Related Disorder Reveals Characteristic Brain Malformations.

AJNR. American journal of neuroradiology·2026
Same journal

ASNR-ESNR White Paper on Sustainability in Neuroradiology.

AJNR. American journal of neuroradiology·2026
Same journal

Intracranial Atherosclerotic Disease Distribution Across Circle of Willis Segments: Insights from CREST-H.

AJNR. American journal of neuroradiology·2026
See all related articles

Related Experiment Video

Updated: Feb 16, 2026

Dual-phase Cone-beam Computed Tomography to See, Reach, and Treat Hepatocellular Carcinoma during Drug-eluting Beads Transarterial Chemo-embolization
09:49

Dual-phase Cone-beam Computed Tomography to See, Reach, and Treat Hepatocellular Carcinoma during Drug-eluting Beads Transarterial Chemo-embolization

Published on: December 2, 2013

10.8K

Beware of Multiphase CTA Interpretation

E Raz1, M Shapiro1

  • 1Radiology Department, Neurointerventional Radiology Section New York University Langone Medical Center New York, New York.

AJNR. American Journal of Neuroradiology
|December 16, 2017
PubMed
Summary

No abstract available in PubMed .

More Related Videos

Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging
09:32

Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging

Published on: December 9, 2021

3.5K
Phase Diagram Characterization Using Magnetic Beads as Liquid Carriers
12:37

Phase Diagram Characterization Using Magnetic Beads as Liquid Carriers

Published on: September 4, 2015

13.0K

Related Experiment Videos

Last Updated: Feb 16, 2026

Dual-phase Cone-beam Computed Tomography to See, Reach, and Treat Hepatocellular Carcinoma during Drug-eluting Beads Transarterial Chemo-embolization
09:49

Dual-phase Cone-beam Computed Tomography to See, Reach, and Treat Hepatocellular Carcinoma during Drug-eluting Beads Transarterial Chemo-embolization

Published on: December 2, 2013

10.8K
Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging
09:32

Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging

Published on: December 9, 2021

3.5K
Phase Diagram Characterization Using Magnetic Beads as Liquid Carriers
12:37

Phase Diagram Characterization Using Magnetic Beads as Liquid Carriers

Published on: September 4, 2015

13.0K