Related Experiment Video
Updated: Feb 16, 2026

A Simplified Stepwise Approach to Echo Guidance during Percutaneous Mitral Valve Repair
Published on: October 16, 2021
How to Adjust Neochordae Length Accurately in Degenerative Mitral Regurgitation
Jorge Rodriguez-Roda1, Javier Miguelena1, Jose Lopez1
1Department of Cardiac Surgery, University Hospital Ramon y Cajal, Madrid, Spain.
Abstract:
We describe a simple technique for the accurate adjustment of polytetrafluoroethylene neochordae length in degenerative mitral regurgitation using the annuloplasty ring's own suture as a reference instead of using sophisticated or less precise maneuvers. Two threads of the annuloplasty ring suture are placed at the level of the mitral valve annulus plane to be used as a reference to tie the neochordae.
More Related Videos
Related Concept Videos
Mitral Regurgitation III: Medical Management
Mitral Regurgitation IV: Nursing Management
Mitral Regurgitation I: Introduction
Mitral Stenosis III: Medical Management
Mitral Valve Prolapse II: Assessment and Management
Mitral Regurgitation II: Clinical Features and Diagnostic Tests