Related Experiment Video
Updated: Feb 16, 2026

Measurement of Aerosols Optical Thickness of the Atmosphere using the GLOBE Handheld Sun Photometer
Published on: May 29, 2019
Performance assessment of a portable nephelometer for outdoor particle mass measurement
Zhanyong Wang1, Dongsheng Wang, Zhong-Ren Peng
1School of Engineering, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Intelligent Transportation System, Guangzhou 510006, China. wangzhy75@mail.sysu.edu.cn caiming@mail.sysu.edu.cn.
Abstract:
The availability of portable nephelometers has improved assessment of exposure to atmospheric particles at a high resolution regarding space and time. However, nephelometer performance has seldom been evaluated for outdoor measurements, especially in Chinese cities. During 37 days of measurements at four outdoor sites in Shanghai, we assessed a popular nephelometer called SidePak (TSI Inc., USA) for PM1.0, PM2.5 and PM10 mass measurements and compared them to US federal reference methods (FRMs) based on different measurement principles. The nephelometer showed high measurement precision and stability and was strongly correlated with FRMs, making it superior to the portable light scattering monitors reported in the past and thus indicating the maturity of this principle. The nephelometer measurements overestimated all those of FRMs by a factor of two, which is higher than in evaluations in other international cities. This overestimation showed a descending order for PM1.0 (2.9-fold), PM2.5 (2.2-fold) and PM10 (1.9-fold) relative to the FRMs of tapered element oscillating microbalance or beta attenuation combined with nephelometry, based on whole samples. Sites that are far from direct pollution sources showed very good agreement between the nephelometer and FRMs for PM2.5 mass measurements, while, by comparison, the roadside site showed a lower SidePak/FRM PM2.5 ratio, which is likely due to higher abundance of elemental carbon in roadside particles. Relative humidity (RH) was shown to be a key factor that distorted the measurement of the nephelometer. An empirical formula incorporating an RH adjustment developed to correct the nephelometer could produce a reasonable result, even across the various sites. This study demonstrates the great potential of the nephelometer for outdoor particle mass measurements, but for accurate and comparable data, a site-specific calibration is strongly recommended before using.
More Related Videos
Related Concept Videos
Precipitation Gravimetry
In determining nickel by gravimetric analysis, a precipitant of ethanolic dimethylglyoxime is added to a hot nickel salt solution. This is quickly followed by the dropwise addition of dilute ammonia solution until precipitation occurs. A...
Gravimetry: Overview
In precipitation gravimetry, the analyte is converted into a precipitate and weighed. For example, the silver content in a sample can be estimated by precipitating and...

