Correspondence between fiber post and drill dimensions for post canal preparation
Ricardo Pablo Portigliatti1, José Luis Tumini1, Alejandro Daniel Bertoldi Hepburn2
1Endodontic Postgraduate Program, Maimónides University, Buenos Aires, Argentina.
American Journal of Dentistry
|December 19, 2017
Summary
Significant size discrepancies exist between fiber posts and their corresponding endodontic drills. This poor fit can compromise cement thickness, potentially reducing bond strength and leading to critical stresses in dental restorations.
Area of Science:
- Dental Materials Science
- Endodontics
- Biomaterials Engineering
Background:
- Fiber posts are widely used in endodontic restorations.
- Accurate sizing of posts and preparation drills is crucial for successful cementation.
- Discrepancies can impact the integrity of the final restoration.
Purpose of the Study:
- To compare the dimensional accuracy between fiber posts and their corresponding root canal preparation drills.
- To evaluate the spatial correspondence of different post systems and drill calibers.
Main Methods:
- Three major endodontic post brands (Exacto, ParaPost Taper Lux, Macro-Lock Illusion X-RO) and their drills were analyzed.
- Scanning electron microscopy (SEM) was used to microphotograph posts and drills.
- ImageJ software analyzed post and drill diameters at the apical extreme (Pd0, Dd0) and 5mm from the apex (Pd5, Dd5).
- Statistical analysis was performed using the student t-test.
Main Results:
- Exacto posts (0.5) were larger than their drills at the apical extreme (Pd0).
- ParaPost drills (4.5, 5, 5.5) were significantly larger than their corresponding posts at the apical extreme (Dd0).
- Exacto posts (0.5, 1) were larger than their drills at 5mm from the apex (Pd5), while Exacto post 2 was smaller.
- Macro-Lock drills (4) and ParaPost drills (5) were larger than their posts at 5mm from the apex (Dd5).
Conclusions:
- A notable lack of spatial correspondence exists between many fiber posts and their associated preparation drills.
- This dimensional mismatch can lead to suboptimal luting cement film thickness.
- Compromised cement thickness can diminish bond strength and potentially induce critical stresses within the restoration.