Related Experiment Video
Updated: Feb 16, 2026

Contrast-Enhanced Subharmonic Aided Pressure Estimation SHAPE Using Ultrasound Imaging with a Focus on Identifying Portal Hypertension
Published on: December 5, 2020
Noninvasive Assessment of Intra-Abdominal Pressure Using Ultrasound-Guided Tonometry: A Proof-of-Concept Study
Andreas Bloch1, Michael Glas1, Andreas Kohler2
1Department of Intensive Care Medicine, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland.
Background:
Intra-abdominal hypertension jeopardizes abdominal organ perfusion and venous return. Contemporary recognition of elevated intra-abdominal pressure (IAP) plays a crucial role in reducing mortality and morbidity. We evaluated ultrasound-guided tonometry in this context hypothesizing that the vertical chamber diameter of this device inversely correlates with IAP.
Methods:
IAP was increased in six 5 mmHg steps to 40 mmHg by instillation of normal saline into the peritoneal cavity of eight anesthetized pigs. Liver and renal blood flows (ultrasound transit time), intravesical, intraperitoneal, and end-inspiratory plateau pressures were recorded. For ultrasound-based assessment of IAP (ultrasound-guided tonometry), a pressure-transducing, compressible chamber was fixed at the tip of a linear ultrasound probe, and the system was applied on the abdominal wall using different predetermined levels of external pressure. At each IAP level (reference: intravesical pressure), two investigators measured the vertical diameter of this chamber.
Results:
All abdominal flows decreased (by 39%-58%), and end-inspiratory plateau pressure increased from 15 mbar (14-17 mbar) to 38 mbar (33-42 mbar) (median, range) with increasing IAP (all P < 0.01). Vertical chamber diameter decreased from 14.9 (14.6-15.2) mm to12.8 (12.4-13.4) mm with increasing IAP. Coefficients of variations between and within observers regarding change of the vertical tonometry chamber diameter were small (all <4%), and the results were independent of the externally applied pressure level on the ultrasound probe. Correlation of IAP and vertical pressure chamber distance was highly significant (r = -1, P = 0.0004). Ultrasound-guided tonometry could discriminate between normal (baseline) pressure and 15 mmHg, between 15 and 25 mmHg) and between 25 and 40 mmHg IAP (all P ≤ 0.18). Similar results were obtained for end-inspiratory plateau pressures.
Conclusions:
In our model, values obtained by ultrasound-guided tonometry correlated significantly with IAPs. The method was able to discriminate between normal, moderately, and markedly increased IAP values.
More Related Videos
Related Concept Videos
Ultrasound I: Abdominal Ultrasonography
Abdominal ultrasonography, commonly known as abdominal ultrasound, is a vital, non-invasive medical imaging technique widely used in healthcare.
Procedure:
This diagnostic tool allows the clinician to visually inspect internal structures within the abdomen, including vital organs such as the liver, gallbladder, pancreas, kidneys, and spleen.
The abdominal ultrasound process begins with applying a special gel to the patient's skin over the abdomen. This gel enhances the...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessment of the Abdomen II: Percussion
Percussion
Percussion is an essential...
Imaging Studies II: Ultrasonography