A Package of Established Analytical Tools to Investigate the Solid-State Alteration of Lipid-Based Excipients
Published on: August 9, 2022
Electron microscopy/energy dispersive X-ray spectroscopy of drug distribution in solid dispersions and interpretation
Renata Abreu-Villela1, Camille Adler2, Isidoro Caraballo3
1Department of Pharmacy and Pharmaceutical Technology, Universidad de Sevilla, C/Profesor García González 2, 41012, Seville, Spain; University of Applied Sciences and Arts Northwestern Switzerland, Institute of Pharma Technology, Gründenstrasse 40, 4132 Muttenz, Switzerland.
Abstract:
Much contemporary research of poorly water-soluble drugs focuses on amorphous solid dispersions (SDs) for oral drug delivery. Recently, a multifractal formalism has been introduced to describe the distribution of an inorganic carrier in SDs. The present work attempts to directly image model drugs by means of scanning electron microscopy and energy dispersive X-ray spectroscopy. The compounds amlodipine, felodipine, glyburide, and indomethacine, which include halogens to enable sufficient scattering in energy dispersive X-ray spectroscopy, were employed to prepare SDs with hydroxypropyl methylcellulose acetate succinate (HPMCAS) by using a microwave method. Following chemical imaging, it was demonstrated that drug distribution was best described by multifractals, which was clearly superior to a monofractal assumption. The obtained fractal dimensions were influenced by drug loading and it was possible to detect microstructural changes upon addition of the plasticizer urea. Accordingly, the multifractal approach bears much potential to better explore the analytical results of chemical formulation imaging. Insights can be gained from the microstructural organization of SDs, which is interesting to further study formulation and process factors as well as physical stability.
Related Concept Videos
X-ray Diffraction of Biological Samples
According to Bragg's law, when X-rays strike the sample positioned on a stage, the rays are scattered by the electron clouds around the sample atoms. The X-ray diffraction or scattering is caused by constructive interference of the X-ray waves that reflect off the internal...
Factors Affecting Dissolution: Particle Size and Effective Surface Area
Scanning Electron Microscopy
Fundamental Principles
Accelerated...
In Vitro Drug Dissolution: Alternative Methods
Factors Affecting Dissolution: Drug Permeability, Stability and Stereochemistry