Attended Versus Unattended Blood Pressure Measurement in a Real Life Setting
Frederic Bauer1, Felix S Seibert2, Benjamin Rohn2
1From the Universitätsklinikum Marien Hospital Herne, Medizinische Klinik I, Ruhr-University Bochum, Germany (F.B., F.S.S., B.R., N.B., T.H.W.); General practitioner, Saarbruecken-Bischmisheim, Germany (K.A.R.B.); and General practitioner, Puettlingen, Germany (E.R.). frederic.bauer@elisabethgruppe.de.
Abstract:
The debate on the generalizability of the SPRINT (Systolic Blood Pressure Intervention Trial) findings raised considerable interest in the technique of unattended office blood pressure (BP) measurement. It remains elusive, however, whether unattended BP measurement yields lower values than conventional measurements in a real world setting with subjects consulting their personal general practitioner in a familiar office. We performed a cross-sectional study in 158 patients in 4 general practitioners' offices and compared conventional auscultatory office BP to unattended automated office BP in 107 subjects (group 1) and unattended to attended automated office BP in another 51 subjects (group 2). Unattended BP was calculated as the mean of 3 automated measurements performed in a separate room after 5 minutes of rest. Additionally, patients documented home BP for 7 days after the consultation. Mean auscultatory office, unattended office and home BP were 144.6/81.0, 144.1/79.9, and 135.5/78.3 mm Hg in group 1; unattended and attended automated office BP were 134.2/80.6 and 135.7/80.6 mm Hg in group 2. Systolic attended and unattended office BP values were significantly higher than home BP (P<0.001, P<0.01, respectively). Attended and unattended office BP, however, did neither show a significant difference in group 1 nor in group 2 (P>0.05 each). Bland-Altman analysis revealed a bias of 0.5 mm Hg systolic and 1.1 mm Hg diastolic in group 1 and -1.5 mm Hg systolic and 0 mm Hg diastolic in group 2. In conclusion, the present findings show that unattended and attended office BP measurements achieve comparable results, if measurements take place at a familiar general practitioner's office.
Related Concept Videos
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Measurement of Blood Pressure
Errors occurring during blood pressure monitoring
Several factors...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Pre-Procedural Guidelines for Assessing Blood Pressure