A Multimodal Wide-Field Fourier-Transform Raman Microscope
Published on: December 30, 2025
483
Crossed Czerny-Turner Spectrometer with Extended Spectrum Using Movable Planar Mirrors
11 87786 Instrument Technology Research Center, National Applied Research Laboratories, Taiwan, Republic of China.
Applied Spectroscopy
|December 21, 2017
Summary
This study introduces a Czerny-Turner spectrometer with multiple mirrors, significantly expanding spectral range. This cost-effective design enhances spectral coverage without compromising resolution.
Area of Science:
- Optical Engineering
- Spectroscopy
Background:
- Czerny-Turner spectrometers are widely used but have limited spectral range.
- Extending spectral coverage often requires complex or expensive modifications.
Purpose of the Study:
- To develop a cost-effective method for extending the spectral range of Czerny-Turner spectrometers.
- To demonstrate a spectrometer design that achieves thrice the spectral range of a conventional unit.
Main Methods:
- A modified Czerny-Turner spectrometer design incorporating two movable mirrors and one stationary planar mirror.
- Experimental validation of the multi-mirror configuration for spectral band extension.
- Analysis of mirror movement orthogonality to minimize spectral repeatability impact.
Main Results:
- The demonstrated spectrometer design successfully provides two additional spectral bands, tripling the original spectral range.
- Identical optical parameters were maintained across the three spectral bands.
- Orthogonal mirror movement minimized the impact on spectral repeatability.
Conclusions:
- The multi-mirror approach effectively extends spectral coverage in Czerny-Turner spectrometers.
- This method offers a cost-effective solution for rapid spectral inspection with broad applicability.
- The technique can be generalized to enhance spectral range in various spectrometer types without resolution loss.
Related Concept Videos
IR Spectrometers
2.7K
There are two main infrared (IR) spectrophotometers: dispersive IR spectrometers and Fourier transform infrared (FTIR) spectrometers. In a dispersive IR spectrometer, a beam of infrared radiation produced by a hot wire is divided into two parallel equal-intensity beams using mirrors. One beam passes through the sample, while another is a reference beam. The beams then move through the monochromator, which separates the radiations into a continuous spectrum of different frequencies. The...
2.7K
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
796
Inductively coupled plasma (ICP) is the common plasma source used in atomic emission spectroscopy (AES), a technique that detects and analyzes various elements in a sample. This method is often called inductively coupled plasma atomic emission spectroscopy (ICP-AES).
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
796
Atomic Emission Spectroscopy: Instrumentation
1.3K
The instrumentation of atomic emission spectrometry (AES) involves various components, including atomization devices that convert samples into gas-phase atoms and ions. There are two main types of atomization devices: continuous and discrete atomizers. Continuous atomizers, like plasmas and flames, introduce samples in a constant stream, while discrete atomizers inject individual samples using syringes or autosamplers. The most common discrete atomizer is the electrothermal atomizer.
1.3K
UV–Vis Spectrometers
3.8K
The absorbance of UV and visible (UV–visible) radiations is measured using a UV–visible spectrophotometer. Deuterium lamps, which emit UV radiation, and tungsten lamps, which produce radiation in the visible region, are used as light sources in UV–visible spectrophotometers. A monochromator or prism is used for diffraction grating, i.e., to split the incoming radiation into different wavelengths. A system of slits is used to focus the desired wavelength on the sample cell.
3.8K
Atomic Absorption Spectroscopy: Instrumentation
1.8K
An atomic absorption spectrophotometer (AAS) comprises several components: a radiation source, an atomizer, a monochromator, and a detector. The radiation source can be a hollow-cathode lamp (HCL) or an electrodeless-discharge lamp (EDL), both of which provide a narrow emission line of the required wavelength. However, some instruments use continuum sources and high-resolution monochromators to achieve a narrow range of radiation.
The atomizer used in AAS can be either a flame atomizer or an...
The atomizer used in AAS can be either a flame atomizer or an...
1.8K
Tandem Mass Spectrometry
2.6K
Tandem mass spectrometry is a technique that uses multiple mass analyzers in series to obtain a higher selectivity and reduce chemical noise during analyte detection. Instruments with multiple analyzers separated by an interaction cell enable secondary fragmentation and selected study of the fragment ions.Secondary fragmentations occur in the interaction cell and can be induced by various factors. Fragmentation induced by collision with inert gases, such as N2, Ar, He, etc., is called...
2.6K