Related Experiment Video
Updated: Feb 16, 2026

Assessment of Global Ocular Structure Following Spaceflight Using a Micro-Computed Tomography Micro-CT Imaging Method
Published on: October 27, 2020
Computed Tomographic Analysis of the Sagittal Orbit-globe Relationship
Zachary R Abramson1, Srinivas M Susarla2, Anand R Kumar3
1Department of Radiology, University of Tennessee Health Science Center, Memphis, TN, USA.
Accurately measuring the orbit-globe relationship is vital for planning craniofacial surgery. This study presents a CT-based method for precise measurement, ideal for pediatric patients.
Area of Science:
- Craniofacial Surgery
- Medical Imaging
- Ophthalmology
Background:
- Accurate assessment of the orbit-globe relationship is crucial for surgical planning in craniofacial deformities.
- Existing methods may require patient cooperation, limiting their use in pediatric cases.
Purpose of the Study:
- To present a computed tomography (CT)-based technical proof of principle for measuring the sagittal orbit-globe relationship.
- To establish the mathematical basis for this novel measurement technique.
Main Methods:
- Development of a CT-based measurement technique for the sagittal orbit-globe relationship.
- The method is designed to be independent of subject cooperation.
Main Results:
- Demonstration of a technical proof of principle for the CT-based measurement.
- Establishment of the mathematical framework for quantifying the orbit-globe relationship.
Conclusions:
- The described CT-based technique provides a reliable method for assessing the sagittal orbit-globe relationship.
- This non-cooperative technique is optimal for pediatric craniofacial surgical treatment planning and outcome evaluation.
Related Concept Videos
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Anatomy of the Eyeball
Accessory Structures of the Eye
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...